Question 280A dual-controller FC SAN has one host path through one fabric, and the design assumes controller HA alone guarantees no host access interruption during a fabric outage. Which durable operational control best prevents this issue from recurring? Test multipathing after adapter, driver and SAN target changes. Keep separate NVMe versus SCSI connectivity checklists with version support verification. Audit dual-fabric zoning, WWPN inventory and MPIO after SAN fabric changes. Keep a documented path-count budget for every SAN host platform. ExplanationCorrect Answer C:Audit dual-fabric zoning, WWPN inventory and MPIO after SAN fabric changes. This addresses the recurring cause: Controller HA cannot repair a missing independent host-to-target fabric path; host MPIO chooses surviving paths. It keeps the accepted correction in place: Provide redundant FC fabric paths and supported host multipathing to the mapped LUN. Other Answers A:Test multipathing after adapter, driver and SAN target changes. This safeguard targets a different repeat failure: A host sees multiple copies of the same LUN as separate disks after a SAN path expansion, raising a risk of file-system corruption. For the present risk, the necessary control is: Audit dual-fabric zoning, WWPN inventory and MPIO after SAN fabric changes. B:Keep separate NVMe versus SCSI connectivity checklists with version support verification. This safeguard targets a different repeat failure: A team evaluates NVMe over Fibre Channel for a supported host, but assumes conventional FC LUN igroups and SCSI multipathing rules can be reused unchanged. For the present risk, the necessary control is: Audit dual-fabric zoning, WWPN inventory and MPIO after SAN fabric changes. D:Keep a documented path-count budget for every SAN host platform. This safeguard targets a different repeat failure: A SAN architect expects eight storage ports on several nodes to be visible to every host even though host path limits may be exceeded. For the present risk, the necessary control is: Audit dual-fabric zoning, WWPN inventory and MPIO after SAN fabric changes.
Question 281An iSCSI SVM has a single data LIF, and a scheduled port-maintenance event disconnects a business-critical LUN even though the partner controller is healthy. What should the administrator implement first to address the underlying gap? Create an igroup containing the host's initiator IQN and map the intended LUN to that igroup. Provide redundant FC fabric paths and supported host multipathing to the mapped LUN. Configure supported redundant iSCSI target connectivity and host multipathing across appropriate interfaces. Install and configure the supported host multipathing stack so multiple ALUA paths are presented as one logical device. ExplanationCorrect Answer C:Configure supported redundant iSCSI target connectivity and host multipathing across appropriate interfaces. A reachable LUN mapping is insufficient if the network transport has only one path to the initiator. Acceptance requires: Observe session count and sustained I/O while a selected target interface is made unavailable. Other Answers A:Create an igroup containing the host's initiator IQN and map the intended LUN to that igroup. This responds to another san solutions issue: A Linux database host sees an iSCSI target but cannot see its new ONTAP LUN because the administrator created only the LUN, not the host-access mapping. Its mechanism is: LUN existence on an SVM does not expose a block device until an authorized initiator has a LUN mapping. The present case instead requires: Configure supported redundant iSCSI target connectivity and host multipathing across appropriate interfaces. B:Provide redundant FC fabric paths and supported host multipathing to the mapped LUN. This responds to another san solutions issue: A dual-controller FC SAN has one host path through one fabric, and the design assumes controller HA alone guarantees no host access interruption during a fabric outage. Its mechanism is: Controller HA cannot repair a missing independent host-to-target fabric path; host MPIO chooses surviving paths. The present case instead requires: Configure supported redundant iSCSI target connectivity and host multipathing across appropriate interfaces. D:Install and configure the supported host multipathing stack so multiple ALUA paths are presented as one logical device. This responds to another san solutions issue: A host sees multiple copies of the same LUN as separate disks after a SAN path expansion, raising a risk of file-system corruption. Its mechanism is: Without correct MPIO, the OS may interpret multiple paths to one LUN as independent disks rather than one device. The present case instead requires: Configure supported redundant iSCSI target connectivity and host multipathing across appropriate interfaces.
Question 282An iSCSI SVM has a single data LIF, and a scheduled port-maintenance event disconnects a business-critical LUN even though the partner controller is healthy. Which storage-system mechanism is the decisive factor in this situation? LUN existence on an SVM does not expose a block device until an authorized initiator has a LUN mapping. Controller HA cannot repair a missing independent host-to-target fabric path; host MPIO chooses surviving paths. A reachable LUN mapping is insufficient if the network transport has only one path to the initiator. Without correct MPIO, the OS may interpret multiple paths to one LUN as independent disks rather than one device. ExplanationCorrect Answer C:A reachable LUN mapping is insufficient if the network transport has only one path to the initiator. The corrective design is: Configure supported redundant iSCSI target connectivity and host multipathing across appropriate interfaces. A relevant test is: Observe session count and sustained I/O while a selected target interface is made unavailable. Other Answers A:LUN existence on an SVM does not expose a block device until an authorized initiator has a LUN mapping. That mechanism fits a different san solutions failure: A Linux database host sees an iSCSI target but cannot see its new ONTAP LUN because the administrator created only the LUN, not the host-access mapping. Here the decisive mechanism is: A reachable LUN mapping is insufficient if the network transport has only one path to the initiator. B:Controller HA cannot repair a missing independent host-to-target fabric path; host MPIO chooses surviving paths. That mechanism fits a different san solutions failure: A dual-controller FC SAN has one host path through one fabric, and the design assumes controller HA alone guarantees no host access interruption during a fabric outage. Here the decisive mechanism is: A reachable LUN mapping is insufficient if the network transport has only one path to the initiator. D:Without correct MPIO, the OS may interpret multiple paths to one LUN as independent disks rather than one device. That mechanism fits a different san solutions failure: A host sees multiple copies of the same LUN as separate disks after a SAN path expansion, raising a risk of file-system corruption. Here the decisive mechanism is: A reachable LUN mapping is insufficient if the network transport has only one path to the initiator.
Question 283An iSCSI SVM has a single data LIF, and a scheduled port-maintenance event disconnects a business-critical LUN even though the partner controller is healthy. Which test would directly demonstrate that the required behavior now works? Observe session count and sustained I/O while a selected target interface is made unavailable. Check the host initiator IQN, inspect the mapping and rescan to confirm only the assigned LUN appears. Disable one FC fabric in a controlled test and confirm the host I/O continues through an alternate path. Inspect host multipath identity and confirm all eligible paths resolve to a single disk with controlled path failover. ExplanationCorrect Answer A:Observe session count and sustained I/O while a selected target interface is made unavailable. This checks whether the remediation works: Configure supported redundant iSCSI target connectivity and host multipathing across appropriate interfaces. The governing behavior is: A reachable LUN mapping is insufficient if the network transport has only one path to the initiator. Other Answers B:Check the host initiator IQN, inspect the mapping and rescan to confirm only the assigned LUN appears. That check tests the separate condition: A Linux database host sees an iSCSI target but cannot see its new ONTAP LUN because the administrator created only the LUN, not the host-access mapping. It would not establish the required result here: Observe session count and sustained I/O while a selected target interface is made unavailable. C:Disable one FC fabric in a controlled test and confirm the host I/O continues through an alternate path. That check tests the separate condition: A dual-controller FC SAN has one host path through one fabric, and the design assumes controller HA alone guarantees no host access interruption during a fabric outage. It would not establish the required result here: Observe session count and sustained I/O while a selected target interface is made unavailable. D:Inspect host multipath identity and confirm all eligible paths resolve to a single disk with controlled path failover. That check tests the separate condition: A host sees multiple copies of the same LUN as separate disks after a SAN path expansion, raising a risk of file-system corruption. It would not establish the required result here: Observe session count and sustained I/O while a selected target interface is made unavailable.
Question 284An iSCSI SVM has a single data LIF, and a scheduled port-maintenance event disconnects a business-critical LUN even though the partner controller is healthy. What ongoing safeguard should be added to the ONTAP change process? Require per-host igroup/LUN mapping validation in SAN provisioning templates. Audit dual-fabric zoning, WWPN inventory and MPIO after SAN fabric changes. Standardize at least two independent target paths and supported host multipath policies. Test multipathing after adapter, driver and SAN target changes. ExplanationCorrect Answer C:Standardize at least two independent target paths and supported host multipath policies. This addresses the recurring cause: A reachable LUN mapping is insufficient if the network transport has only one path to the initiator. It keeps the accepted correction in place: Configure supported redundant iSCSI target connectivity and host multipathing across appropriate interfaces. Other Answers A:Require per-host igroup/LUN mapping validation in SAN provisioning templates. This safeguard targets a different repeat failure: A Linux database host sees an iSCSI target but cannot see its new ONTAP LUN because the administrator created only the LUN, not the host-access mapping. For the present risk, the necessary control is: Standardize at least two independent target paths and supported host multipath policies. B:Audit dual-fabric zoning, WWPN inventory and MPIO after SAN fabric changes. This safeguard targets a different repeat failure: A dual-controller FC SAN has one host path through one fabric, and the design assumes controller HA alone guarantees no host access interruption during a fabric outage. For the present risk, the necessary control is: Standardize at least two independent target paths and supported host multipath policies. D:Test multipathing after adapter, driver and SAN target changes. This safeguard targets a different repeat failure: A host sees multiple copies of the same LUN as separate disks after a SAN path expansion, raising a risk of file-system corruption. For the present risk, the necessary control is: Standardize at least two independent target paths and supported host multipath policies.
Question 285A Windows cluster shares a SAN LUN with two nodes but only one node's initiator appears in the igroup and failover leaves the second host unable to access storage. Which proposed action best resolves the specific issue without broadening access or risk? Include the approved initiators of both cluster members in the correct igroup and verify host cluster disk ownership rules. Create an igroup containing the host's initiator IQN and map the intended LUN to that igroup. Use the host-appropriate supported OS type and confirm initiator group/provisioning alignment before mapping. Apply supported Selective LUN Map, zoning or portsets to bound target paths while retaining redundancy. ExplanationCorrect Answer A:Include the approved initiators of both cluster members in the correct igroup and verify host cluster disk ownership rules. Cluster failover depends on each authorized node having a valid mapped path to the shared LUN. Acceptance requires: Move the clustered role between nodes in a test and confirm both have correct LUN visibility and consistent identifiers. Other Answers B:Create an igroup containing the host's initiator IQN and map the intended LUN to that igroup. This responds to another san solutions issue: A Linux database host sees an iSCSI target but cannot see its new ONTAP LUN because the administrator created only the LUN, not the host-access mapping. Its mechanism is: LUN existence on an SVM does not expose a block device until an authorized initiator has a LUN mapping. The present case instead requires: Include the approved initiators of both cluster members in the correct igroup and verify host cluster disk ownership rules. C:Use the host-appropriate supported OS type and confirm initiator group/provisioning alignment before mapping. This responds to another san solutions issue: An administrator creates an iSCSI LUN for a Linux host but selects an unrelated Windows OS type in its igroup and LUN settings. Its mechanism is: The configured host OS type influences ONTAP SAN device behavior and cannot be treated as cosmetic metadata. The present case instead requires: Include the approved initiators of both cluster members in the correct igroup and verify host cluster disk ownership rules. D:Apply supported Selective LUN Map, zoning or portsets to bound target paths while retaining redundancy. This responds to another san solutions issue: A SAN architect expects eight storage ports on several nodes to be visible to every host even though host path limits may be exceeded. Its mechanism is: More exposed targets are not automatically better; supported host/ONTAP multipath limits and optimized ownership matter. The present case instead requires: Include the approved initiators of both cluster members in the correct igroup and verify host cluster disk ownership rules.
Question 286A Windows cluster shares a SAN LUN with two nodes but only one node's initiator appears in the igroup and failover leaves the second host unable to access storage. Which ONTAP behavior explains why the original approach does not meet the requirement? LUN existence on an SVM does not expose a block device until an authorized initiator has a LUN mapping. Cluster failover depends on each authorized node having a valid mapped path to the shared LUN. The configured host OS type influences ONTAP SAN device behavior and cannot be treated as cosmetic metadata. More exposed targets are not automatically better; supported host/ONTAP multipath limits and optimized ownership matter. ExplanationCorrect Answer B:Cluster failover depends on each authorized node having a valid mapped path to the shared LUN. The corrective design is: Include the approved initiators of both cluster members in the correct igroup and verify host cluster disk ownership rules. A relevant test is: Move the clustered role between nodes in a test and confirm both have correct LUN visibility and consistent identifiers. Other Answers A:LUN existence on an SVM does not expose a block device until an authorized initiator has a LUN mapping. That mechanism fits a different san solutions failure: A Linux database host sees an iSCSI target but cannot see its new ONTAP LUN because the administrator created only the LUN, not the host-access mapping. Here the decisive mechanism is: Cluster failover depends on each authorized node having a valid mapped path to the shared LUN. C:The configured host OS type influences ONTAP SAN device behavior and cannot be treated as cosmetic metadata. That mechanism fits a different san solutions failure: An administrator creates an iSCSI LUN for a Linux host but selects an unrelated Windows OS type in its igroup and LUN settings. Here the decisive mechanism is: Cluster failover depends on each authorized node having a valid mapped path to the shared LUN. D:More exposed targets are not automatically better; supported host/ONTAP multipath limits and optimized ownership matter. That mechanism fits a different san solutions failure: A SAN architect expects eight storage ports on several nodes to be visible to every host even though host path limits may be exceeded. Here the decisive mechanism is: Cluster failover depends on each authorized node having a valid mapped path to the shared LUN.
Question 287A Windows cluster shares a SAN LUN with two nodes but only one node's initiator appears in the igroup and failover leaves the second host unable to access storage. Which observation provides the strongest evidence that the issue was corrected? Check the host initiator IQN, inspect the mapping and rescan to confirm only the assigned LUN appears. Move the clustered role between nodes in a test and confirm both have correct LUN visibility and consistent identifiers. Compare configured LUN and igroup OS types with NetApp host interoperability guidance and rescan the intended host. Compare discovered target paths with the host support matrix and confirm resilient access after limiting paths. ExplanationCorrect Answer B:Move the clustered role between nodes in a test and confirm both have correct LUN visibility and consistent identifiers. This checks whether the remediation works: Include the approved initiators of both cluster members in the correct igroup and verify host cluster disk ownership rules. The governing behavior is: Cluster failover depends on each authorized node having a valid mapped path to the shared LUN. Other Answers A:Check the host initiator IQN, inspect the mapping and rescan to confirm only the assigned LUN appears. That check tests the separate condition: A Linux database host sees an iSCSI target but cannot see its new ONTAP LUN because the administrator created only the LUN, not the host-access mapping. It would not establish the required result here: Move the clustered role between nodes in a test and confirm both have correct LUN visibility and consistent identifiers. C:Compare configured LUN and igroup OS types with NetApp host interoperability guidance and rescan the intended host. That check tests the separate condition: An administrator creates an iSCSI LUN for a Linux host but selects an unrelated Windows OS type in its igroup and LUN settings. It would not establish the required result here: Move the clustered role between nodes in a test and confirm both have correct LUN visibility and consistent identifiers. D:Compare discovered target paths with the host support matrix and confirm resilient access after limiting paths. That check tests the separate condition: A SAN architect expects eight storage ports on several nodes to be visible to every host even though host path limits may be exceeded. It would not establish the required result here: Move the clustered role between nodes in a test and confirm both have correct LUN visibility and consistent identifiers.
Question 288A Windows cluster shares a SAN LUN with two nodes but only one node's initiator appears in the igroup and failover leaves the second host unable to access storage. Which preventive practice most directly reduces recurrence of this failure? Require per-host igroup/LUN mapping validation in SAN provisioning templates. Validate host platform, protocol and OS type in the SAN provisioning request. Update igroup membership as part of clustered host additions and removals. Keep a documented path-count budget for every SAN host platform. ExplanationCorrect Answer C:Update igroup membership as part of clustered host additions and removals. This addresses the recurring cause: Cluster failover depends on each authorized node having a valid mapped path to the shared LUN. It keeps the accepted correction in place: Include the approved initiators of both cluster members in the correct igroup and verify host cluster disk ownership rules. Other Answers A:Require per-host igroup/LUN mapping validation in SAN provisioning templates. This safeguard targets a different repeat failure: A Linux database host sees an iSCSI target but cannot see its new ONTAP LUN because the administrator created only the LUN, not the host-access mapping. For the present risk, the necessary control is: Update igroup membership as part of clustered host additions and removals. B:Validate host platform, protocol and OS type in the SAN provisioning request. This safeguard targets a different repeat failure: An administrator creates an iSCSI LUN for a Linux host but selects an unrelated Windows OS type in its igroup and LUN settings. For the present risk, the necessary control is: Update igroup membership as part of clustered host additions and removals. D:Keep a documented path-count budget for every SAN host platform. This safeguard targets a different repeat failure: A SAN architect expects eight storage ports on several nodes to be visible to every host even though host path limits may be exceeded. For the present risk, the necessary control is: Update igroup membership as part of clustered host additions and removals.
Question 289A host sees multiple copies of the same LUN as separate disks after a SAN path expansion, raising a risk of file-system corruption. Which ONTAP administration step most directly corrects this failure? Provide redundant FC fabric paths and supported host multipathing to the mapped LUN. Install and configure the supported host multipathing stack so multiple ALUA paths are presented as one logical device. Create an igroup containing the host's initiator IQN and map the intended LUN to that igroup. Use the host-appropriate supported OS type and confirm initiator group/provisioning alignment before mapping. ExplanationCorrect Answer B:Install and configure the supported host multipathing stack so multiple ALUA paths are presented as one logical device. Without correct MPIO, the OS may interpret multiple paths to one LUN as independent disks rather than one device. Acceptance requires: Inspect host multipath identity and confirm all eligible paths resolve to a single disk with controlled path failover. Other Answers A:Provide redundant FC fabric paths and supported host multipathing to the mapped LUN. This responds to another san solutions issue: A dual-controller FC SAN has one host path through one fabric, and the design assumes controller HA alone guarantees no host access interruption during a fabric outage. Its mechanism is: Controller HA cannot repair a missing independent host-to-target fabric path; host MPIO chooses surviving paths. The present case instead requires: Install and configure the supported host multipathing stack so multiple ALUA paths are presented as one logical device. C:Create an igroup containing the host's initiator IQN and map the intended LUN to that igroup. This responds to another san solutions issue: A Linux database host sees an iSCSI target but cannot see its new ONTAP LUN because the administrator created only the LUN, not the host-access mapping. Its mechanism is: LUN existence on an SVM does not expose a block device until an authorized initiator has a LUN mapping. The present case instead requires: Install and configure the supported host multipathing stack so multiple ALUA paths are presented as one logical device. D:Use the host-appropriate supported OS type and confirm initiator group/provisioning alignment before mapping. This responds to another san solutions issue: An administrator creates an iSCSI LUN for a Linux host but selects an unrelated Windows OS type in its igroup and LUN settings. Its mechanism is: The configured host OS type influences ONTAP SAN device behavior and cannot be treated as cosmetic metadata. The present case instead requires: Install and configure the supported host multipathing stack so multiple ALUA paths are presented as one logical device.
Question 290A host sees multiple copies of the same LUN as separate disks after a SAN path expansion, raising a risk of file-system corruption. Which technical distinction most directly explains the observed result? Controller HA cannot repair a missing independent host-to-target fabric path; host MPIO chooses surviving paths. LUN existence on an SVM does not expose a block device until an authorized initiator has a LUN mapping. The configured host OS type influences ONTAP SAN device behavior and cannot be treated as cosmetic metadata. Without correct MPIO, the OS may interpret multiple paths to one LUN as independent disks rather than one device. ExplanationCorrect Answer D:Without correct MPIO, the OS may interpret multiple paths to one LUN as independent disks rather than one device. The corrective design is: Install and configure the supported host multipathing stack so multiple ALUA paths are presented as one logical device. A relevant test is: Inspect host multipath identity and confirm all eligible paths resolve to a single disk with controlled path failover. Other Answers A:Controller HA cannot repair a missing independent host-to-target fabric path; host MPIO chooses surviving paths. That mechanism fits a different san solutions failure: A dual-controller FC SAN has one host path through one fabric, and the design assumes controller HA alone guarantees no host access interruption during a fabric outage. Here the decisive mechanism is: Without correct MPIO, the OS may interpret multiple paths to one LUN as independent disks rather than one device. B:LUN existence on an SVM does not expose a block device until an authorized initiator has a LUN mapping. That mechanism fits a different san solutions failure: A Linux database host sees an iSCSI target but cannot see its new ONTAP LUN because the administrator created only the LUN, not the host-access mapping. Here the decisive mechanism is: Without correct MPIO, the OS may interpret multiple paths to one LUN as independent disks rather than one device. C:The configured host OS type influences ONTAP SAN device behavior and cannot be treated as cosmetic metadata. That mechanism fits a different san solutions failure: An administrator creates an iSCSI LUN for a Linux host but selects an unrelated Windows OS type in its igroup and LUN settings. Here the decisive mechanism is: Without correct MPIO, the OS may interpret multiple paths to one LUN as independent disks rather than one device.