Question 330At fictional Harborview ISP 083, a regional service-provider network, during a two-site transit migration, operations observes: A newly rebooted core router attracts transit traffic while its forwarding state is still being restored. Which Junos forwarding or control-plane rule applies to this case? IS-IS hello PDUs discover and maintain neighbor relationships. The IS-IS overload indication can discourage transit use during control-plane recovery. IS-IS authentication parameters must match for participating routers to exchange protocol information. Link-local IPv6 addresses are scoped to a link and require an appropriate interface context. ExplanationCorrect Answer B:The IS-IS overload indication can discourage transit use during control-plane recovery. Use the supported IS-IS overload behavior during maintenance and remove it when forwarding readiness is verified. Peer SPF paths avoid the router while overloaded and normal paths return after it is cleared. Incorrect Answers A:IS-IS hello PDUs discover and maintain neighbor relationships. It is relevant if an IS-IS neighbor remains down after an interface template disables its hello transmission, but the reported issue is that a newly rebooted core router attracts transit traffic while its forwarding state is still being restored. C:IS-IS authentication parameters must match for participating routers to exchange protocol information. This relates to a case where a provider IS-IS circuit stops forming neighbors after the authentication key is changed on only one end; the current situation is that a newly rebooted core router attracts transit traffic while its forwarding state is still being restored. D:Link-local IPv6 addresses are scoped to a link and require an appropriate interface context. It is useful for situations where an IPv6 adjacency uses a link-local next hop, but its interface scope is omitted from the implementation design; the reported fault, though, is that a newly rebooted core router attracts transit traffic while its forwarding state is still being restored.
Question 331At fictional Harborview ISP 083, a regional service-provider network, during a two-site transit migration, operations observes: A newly rebooted core router attracts transit traffic while its forwarding state is still being restored. What operational evidence best establishes successful remediation? The service route is visible on remote devices while unrelated prefixes remain suppressed. The LSDB lists separate stable system IDs for the two routers. The target prefix has the planned preference while unrelated routes retain prior selection. Peer SPF paths avoid the router while overloaded and normal paths return after it is cleared. ExplanationCorrect Answer D:Peer SPF paths avoid the router while overloaded and normal paths return after it is cleared. The IS-IS overload indication can discourage transit use during control-plane recovery. Use the supported IS-IS overload behavior during maintenance and remove it when forwarding readiness is verified. Incorrect Answers A:The service route is visible on remote devices while unrelated prefixes remain suppressed. This is applicable when a customer service route never reaches another IS-IS area because the required export policy omits it; the present condition is that a newly rebooted core router attracts transit traffic while its forwarding state is still being restored. B:The LSDB lists separate stable system IDs for the two routers. It is relevant if a device cloned from a lab template has the same IS-IS system ID as a production router, but the reported issue is that a newly rebooted core router attracts transit traffic while its forwarding state is still being restored. C:The target prefix has the planned preference while unrelated routes retain prior selection. This could help if a broad routing policy term changes preference for all imported prefixes instead of only the intended test network, but not when a newly rebooted core router attracts transit traffic while its forwarding state is still being restored.
Question 332At fictional Harborview ISP 083, a regional service-provider network, during a two-site transit migration, operations observes: A newly rebooted core router attracts transit traffic while its forwarding state is still being restored. Which operational harm would persist without the intended correction? The partially initialized router drops transit packets during planned recovery. An important customer service is unreachable outside its local PE. Some routers calculate stale paths and cannot reach required loopbacks. Packets cannot travel the intended MPLS transport path. ExplanationCorrect Answer A:The partially initialized router drops transit packets during planned recovery. The IS-IS overload indication can discourage transit use during control-plane recovery. Use the supported IS-IS overload behavior during maintenance and remove it when forwarding readiness is verified. Incorrect Answers B:An important customer service is unreachable outside its local PE. This is applicable when a customer service route never reaches another IS-IS area because the required export policy omits it; the present condition is that a newly rebooted core router attracts transit traffic while its forwarding state is still being restored. C:Some routers calculate stale paths and cannot reach required loopbacks. It is relevant if a remote PE misses a new loopback route because IS-IS link-state flooding is incomplete after an adjacency reset, but the reported issue is that a newly rebooted core router attracts transit traffic while its forwarding state is still being restored. D:Packets cannot travel the intended MPLS transport path. This could help if an MPLS service route is reachable at IP level but its LDP label binding is missing on one hop, but not when a newly rebooted core router attracts transit traffic while its forwarding state is still being restored.
Question 333In a separate fictional JNCIS-SP lab review for Greenbridge ISP 084, a carrier-edge and core routing team, following a backbone resilience drill, engineers find: A newly rebooted core router attracts transit traffic while its forwarding state is still being restored. What should the Junos specialist change first to resolve this specific fault? Inspect LSDB sequence and flooding state and repair the affected adjacency. Assign a unique network entity title system identifier and verify database identities. Use the supported IS-IS overload behavior during maintenance and remove it when forwarding readiness is verified. Inspect spanning-tree port role, state, and received BPDU information before changing hardware. ExplanationCorrect Answer C:Use the supported IS-IS overload behavior during maintenance and remove it when forwarding readiness is verified. Peer SPF paths avoid the router while overloaded and normal paths return after it is cleared. The IS-IS overload indication can discourage transit use during control-plane recovery. Incorrect Answers A:Inspect LSDB sequence and flooding state and repair the affected adjacency. This could matter when a remote PE misses a new loopback route because IS-IS link-state flooding is incomplete after an adjacency reset. In this case, a newly rebooted core router attracts transit traffic while its forwarding state is still being restored. B:Assign a unique network entity title system identifier and verify database identities. That could help when a device cloned from a lab template has the same IS-IS system ID as a production router; here, a newly rebooted core router attracts transit traffic while its forwarding state is still being restored. D:Inspect spanning-tree port role, state, and received BPDU information before changing hardware. It is relevant if a link is physically up but stays blocked by spanning tree, and an operator incorrectly blames interface optics, but the reported issue is that a newly rebooted core router attracts transit traffic while its forwarding state is still being restored.
Question 334In a separate fictional JNCIS-SP lab review for Greenbridge ISP 084, a carrier-edge and core routing team, following a backbone resilience drill, engineers find: A newly rebooted core router attracts transit traffic while its forwarding state is still being restored. What technical principle underlies the right remedy? IS-IS levels separate routing scope and require a deliberate interlevel reachability design. The IS-IS overload indication can discourage transit use during control-plane recovery. IS-IS authentication parameters must match for participating routers to exchange protocol information. BGP AS path information supports loop avoidance and participates in route selection. ExplanationCorrect Answer B:The IS-IS overload indication can discourage transit use during control-plane recovery. Peer SPF paths avoid the router while overloaded and normal paths return after it is cleared. Use the supported IS-IS overload behavior during maintenance and remove it when forwarding readiness is verified. Incorrect Answers A:IS-IS levels separate routing scope and require a deliberate interlevel reachability design. It addresses a different problem: An L1-only site lacks an approved route to reach destinations in the backbone after a level-transition change. Here, a newly rebooted core router attracts transit traffic while its forwarding state is still being restored. C:IS-IS authentication parameters must match for participating routers to exchange protocol information. That could help when a provider IS-IS circuit stops forming neighbors after the authentication key is changed on only one end; here, a newly rebooted core router attracts transit traffic while its forwarding state is still being restored. D:BGP AS path information supports loop avoidance and participates in route selection. This is applicable when an engineer blames BGP route rejection on local preference while a route carries an unexpected autonomous-system path; the present condition is that a newly rebooted core router attracts transit traffic while its forwarding state is still being restored.
Question 335In a separate fictional JNCIS-SP lab review for Greenbridge ISP 084, a carrier-edge and core routing team, following a backbone resilience drill, engineers find: A newly rebooted core router attracts transit traffic while its forwarding state is still being restored. Which acceptance finding demonstrates the affected service has recovered? The expected neighbor appears with stable hold time and correct interface state. Peer SPF paths avoid the router while overloaded and normal paths return after it is cleared. The remote LSDB includes the fresh LSP and the loopback route becomes active. The expected LSA is present with appropriate advertising router and area context. ExplanationCorrect Answer B:Peer SPF paths avoid the router while overloaded and normal paths return after it is cleared. Use the supported IS-IS overload behavior during maintenance and remove it when forwarding readiness is verified. The IS-IS overload indication can discourage transit use during control-plane recovery. Incorrect Answers A:The expected neighbor appears with stable hold time and correct interface state. That option concerns an IS-IS neighbor remains down after an interface template disables its hello transmission. The problem here is different: A newly rebooted core router attracts transit traffic while its forwarding state is still being restored. C:The remote LSDB includes the fresh LSP and the loopback route becomes active. This could matter when a remote PE misses a new loopback route because IS-IS link-state flooding is incomplete after an adjacency reset. In this case, a newly rebooted core router attracts transit traffic while its forwarding state is still being restored. D:The expected LSA is present with appropriate advertising router and area context. That could help when operators expect a customer prefix from another area but only inspect local interface counters and never examine link-state advertisements; here, a newly rebooted core router attracts transit traffic while its forwarding state is still being restored.
Question 336In a separate fictional JNCIS-SP lab review for Greenbridge ISP 084, a carrier-edge and core routing team, following a backbone resilience drill, engineers find: A newly rebooted core router attracts transit traffic while its forwarding state is still being restored. What is the direct residual network risk if the fault remains unresolved? The partially initialized router drops transit packets during planned recovery. Traffic unexpectedly overloads a low-capacity link. The backbone link stays out of the routing topology or an unsafe bypass is introduced. Subscribers see extended connectivity interruptions after routine link changes. ExplanationCorrect Answer A:The partially initialized router drops transit packets during planned recovery. Use the supported IS-IS overload behavior during maintenance and remove it when forwarding readiness is verified. The IS-IS overload indication can discourage transit use during control-plane recovery. Incorrect Answers B:Traffic unexpectedly overloads a low-capacity link. That option concerns an intended core link metric is truncated by a mismatched metric-style design and fails to shift paths as expected. The problem here is different: A newly rebooted core router attracts transit traffic while its forwarding state is still being restored. C:The backbone link stays out of the routing topology or an unsafe bypass is introduced. It addresses a different problem: A provider IS-IS circuit stops forming neighbors after the authentication key is changed on only one end. Here, a newly rebooted core router attracts transit traffic while its forwarding state is still being restored. D:Subscribers see extended connectivity interruptions after routine link changes. This could matter when a redundant access network takes far too long to recover from a link failure because it uses inappropriate legacy STP behavior. In this case, a newly rebooted core router attracts transit traffic while its forwarding state is still being restored.
Question 337At fictional Fairhaven Broadband 085, a regional service-provider network, during a preproduction design validation, operations observes: A provider IS-IS circuit stops forming neighbors after the authentication key is changed on only one end. Which targeted remediation best fits the reported behavior? Correct area address design or the adjacency level according to the provider topology. Synchronize the approved IS-IS authentication configuration across peers and verify secure adjacency. Restore IS-IS operation and appropriate hello behavior on the intended transit interface. Inspect database-exchange state and repair the adjacency rather than editing unrelated route preferences. ExplanationCorrect Answer B:Synchronize the approved IS-IS authentication configuration across peers and verify secure adjacency. IS-IS authentication parameters must match for participating routers to exchange protocol information. The intended neighbor comes up under the approved authentication settings. Incorrect Answers A:Correct area address design or the adjacency level according to the provider topology. This addresses a situation in which a Level 1 IS-IS adjacency fails between routers with different area addresses even though the physical link is up; however, a provider IS-IS circuit stops forming neighbors after the authentication key is changed on only one end. C:Restore IS-IS operation and appropriate hello behavior on the intended transit interface. That option concerns an IS-IS neighbor remains down after an interface template disables its hello transmission. The problem here is different: A provider IS-IS circuit stops forming neighbors after the authentication key is changed on only one end. D:Inspect database-exchange state and repair the adjacency rather than editing unrelated route preferences. It addresses a different problem: Two supposed adjacent routers have different views of a backbone link because database synchronization never completes. Here, a provider IS-IS circuit stops forming neighbors after the authentication key is changed on only one end.
Question 338At fictional Fairhaven Broadband 085, a regional service-provider network, during a preproduction design validation, operations observes: A provider IS-IS circuit stops forming neighbors after the authentication key is changed on only one end. Why is this particular correction the best fit for the stated defect? IS-IS conveys extensible routing attributes in typed TLVs within protocol packets. IS-IS levels separate routing scope and require a deliberate interlevel reachability design. IS-IS authentication parameters must match for participating routers to exchange protocol information. BGP peers need mutually consistent AS and transport/session parameters. ExplanationCorrect Answer C:IS-IS authentication parameters must match for participating routers to exchange protocol information. Synchronize the approved IS-IS authentication configuration across peers and verify secure adjacency. The intended neighbor comes up under the approved authentication settings. Incorrect Answers A:IS-IS conveys extensible routing attributes in typed TLVs within protocol packets. That relates to circumstances in which a monitoring parser treats a valid IS-IS reachability TLV as an unsupported fault and pages the operations team. Here the problem is that a provider IS-IS circuit stops forming neighbors after the authentication key is changed on only one end. B:IS-IS levels separate routing scope and require a deliberate interlevel reachability design. This addresses a situation in which an L1-only site lacks an approved route to reach destinations in the backbone after a level-transition change; however, a provider IS-IS circuit stops forming neighbors after the authentication key is changed on only one end. D:BGP peers need mutually consistent AS and transport/session parameters. That option concerns an external BGP session never reaches Established because the local peer definition uses the wrong remote AS. The problem here is different: A provider IS-IS circuit stops forming neighbors after the authentication key is changed on only one end.
Question 339At fictional Fairhaven Broadband 085, a regional service-provider network, during a preproduction design validation, operations observes: A provider IS-IS circuit stops forming neighbors after the authentication key is changed on only one end. What direct observation would prove the corrective action worked? All routers compute the expected cost and favor the intended transit route. The remote LSDB includes the fresh LSP and the loopback route becomes active. Tagged prefixes receive the documented policy action and untagged routes are unaffected. The intended neighbor comes up under the approved authentication settings. ExplanationCorrect Answer D:The intended neighbor comes up under the approved authentication settings. IS-IS authentication parameters must match for participating routers to exchange protocol information. Synchronize the approved IS-IS authentication configuration across peers and verify secure adjacency. Incorrect Answers A:All routers compute the expected cost and favor the intended transit route. It is useful for situations where an intended core link metric is truncated by a mismatched metric-style design and fails to shift paths as expected; the reported fault, though, is that a provider IS-IS circuit stops forming neighbors after the authentication key is changed on only one end. B:The remote LSDB includes the fresh LSP and the loopback route becomes active. That relates to circumstances in which a remote PE misses a new loopback route because IS-IS link-state flooding is incomplete after an adjacency reset. Here the problem is that a provider IS-IS circuit stops forming neighbors after the authentication key is changed on only one end. C:Tagged prefixes receive the documented policy action and untagged routes are unaffected. This addresses a situation in which an upstream advertises a community tag to influence treatment but an import policy ignores the agreed meaning; however, a provider IS-IS circuit stops forming neighbors after the authentication key is changed on only one end.
Question 340At fictional Fairhaven Broadband 085, a regional service-provider network, during a preproduction design validation, operations observes: A provider IS-IS circuit stops forming neighbors after the authentication key is changed on only one end. Which failure consequence follows most closely from ignoring this issue? Operators suppress genuine incidents after repeated false IS-IS alerts. The partially initialized router drops transit packets during planned recovery. The backbone link stays out of the routing topology or an unsafe bypass is introduced. A single member fault causes a complete customer circuit outage. ExplanationCorrect Answer C:The backbone link stays out of the routing topology or an unsafe bypass is introduced. IS-IS authentication parameters must match for participating routers to exchange protocol information. Synchronize the approved IS-IS authentication configuration across peers and verify secure adjacency. Incorrect Answers A:Operators suppress genuine incidents after repeated false IS-IS alerts. This relates to a case where a monitoring parser treats a valid IS-IS reachability TLV as an unsupported fault and pages the operations team; the current situation is that a provider IS-IS circuit stops forming neighbors after the authentication key is changed on only one end. B:The partially initialized router drops transit packets during planned recovery. It is useful for situations where a newly rebooted core router attracts transit traffic while its forwarding state is still being restored; the reported fault, though, is that a provider IS-IS circuit stops forming neighbors after the authentication key is changed on only one end. D:A single member fault causes a complete customer circuit outage. This addresses a situation in which a provider assumes a two-member LAG is redundant but has never checked forwarding when one member fails; however, a provider IS-IS circuit stops forming neighbors after the authentication key is changed on only one end.