McAfee Secured

Exam Code: 220-1201

Exam Name: CompTIA A+ Certification Exam: Core 1

Certification Provider: CompTIA

Corresponding Certification: CompTIA A+

100% CompTIA 220-1201 Guaranteed Success With Testking Training Materials

Get Real 220-1201 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

527 Questions & Answers with Testing Engine

"CompTIA A+ Certification Exam: Core 1 Exam", also known as 220-1201 exam, is a CompTIA certification exam.

Pass your tests with the always up-to-date 220-1201 Exam Engine. Your 220-1201 training materials keep you at the head of the pack!

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Was: $137.49
Now: $124.99

CompTIA 220-1201 Practice Test 52

Question 510

A laptop has one replaceable SODIMM but the remaining memory is permanently soldered to the motherboard. Which corrective action is the safest and most direct response?

  1. Install the approved memory form factor for each platform
  2. Populate the channel-paired slots according to the board manual and verify channel mode
  3. Upgrade only the supported replaceable slot while accounting for fixed onboard capacity
  4. Choose a platform and modules that explicitly support working ECC protection

Explanation

Correct Answer

C:

The service manual diagrams onboard memory chips and a single removable socket, consistent with a soldered-onboard ram limits user upgrade options.

Incorrect Answers

A:

The service manual lists SO-DIMM modules while the desktop uses standard DIMM slots, consistent with a sodimm versus full-size dimm form factors.

B:

The motherboard diagram shows the recommended paired slots on separate memory channels, consistent with a dual-channel memory population rules.

D:

The CPU, motherboard and firmware compatibility documents do not confirm ECC operation, consistent with an ecc memory requires supported platform hardware.

Question 511

A technician has authorization to fix the issue: A system supports a lower DDR data rate than a high-speed module's advertised profile and runs the module at a slower standard frequency. What action should be taken next?

  1. Use a supported module density and total memory capacity or upgrade the platform
  2. Use memory of the board-supported DDR generation and supported speed
  3. Verify CPU and board-supported profiles and use stable approved memory timings
  4. Upgrade only the supported replaceable slot while accounting for fixed onboard capacity

Explanation

Correct Answer

C:

Firmware reports the lower negotiated memory rate despite a higher-rated module installed, consistent with a memory clock limited by platform and shared settings.

Incorrect Answers

A:

The service manual's supported module density and total capacity are below the installed specification, consistent with a maximum supported memory capacity or density limitation.

B:

The motherboard supports DDR5 pinout and electrical requirements while the spare is DDR4, consistent with an incompatible ddr memory generation.

D:

The service manual diagrams onboard memory chips and a single removable socket, consistent with a soldered-onboard ram limits user upgrade options.

Question 512

A new workstation needs high random I/O and has an available PCIe-connected M.2 socket; the old SATA SSD saturates the SATA link. Which repair or configuration change addresses the underlying problem?

  1. Use a suitable higher-performance disk or SSD considering workload and capacity
  2. Install a supported NVMe M.2 SSD and verify firmware boot compatibility
  3. Choose a supported SAS HBA or drive compatible with the storage controller
  4. Use an M.2 SATA SSD supported by the slot or a platform offering NVMe

Explanation

Correct Answer

B:

Benchmarking shows the existing drive capped near SATA throughput while the board supports NVMe, consistent with a nvme ssd over pcie for high-throughput storage.

Incorrect Answers

A:

Both drives use magnetic platters but the faster model rotates at 7200 RPM, consistent with a hdd spindle speed influences rotational latency.

C:

The drive connector and controller specifications show SAS disks unsupported by the SATA-only host, consistent with a sas drive requires compatible controller interface.

D:

The device manual specifies SATA-based M.2 storage while the replacement requires PCIe NVMe, consistent with a m.2 physical form factor is not the storage protocol.

Question 513

A maintenance window is available for the following problem: A client has a thin laptop with a SATA M.2 slot only and buys an NVMe-only M.2 drive that fits mechanically but is invisible. Which intervention is most appropriate?

  1. Replace the failed member promptly, monitor the rebuild and maintain independent backups
  2. Choose a supported SAS HBA or drive compatible with the storage controller
  3. Use an M.2 SATA SSD supported by the slot or a platform offering NVMe
  4. Install a supported NVMe M.2 SSD and verify firmware boot compatibility

Explanation

Correct Answer

C:

The device manual specifies SATA-based M.2 storage while the replacement requires PCIe NVMe, consistent with a m.2 physical form factor is not the storage protocol.

Incorrect Answers

A:

The array can operate degraded after one disk failure but cannot tolerate a second concurrent member loss, consistent with a raid 5 single-parity tolerance.

B:

The drive connector and controller specifications show SAS disks unsupported by the SATA-only host, consistent with a sas drive requires compatible controller interface.

D:

Benchmarking shows the existing drive capped near SATA throughput while the board supports NVMe, consistent with a nvme ssd over pcie for high-throughput storage.

Question 514

The owner wants a specific repair, not merely more monitoring: A workstation uses a 5400 RPM mechanical disk and a user complains about slow seeks compared with a supported 7200 RPM disk. What should the technician do?

  1. Install a supported NVMe M.2 SSD and verify firmware boot compatibility
  2. Configure supported RAID 1 and monitor rebuild and backup procedures
  3. Restore from a current backup and redesign with appropriate redundancy if uptime matters
  4. Use a suitable higher-performance disk or SSD considering workload and capacity

Explanation

Correct Answer

D:

Both drives use magnetic platters but the faster model rotates at 7200 RPM, consistent with a hdd spindle speed influences rotational latency.

Incorrect Answers

A:

Benchmarking shows the existing drive capped near SATA throughput while the board supports NVMe, consistent with a nvme ssd over pcie for high-throughput storage.

B:

The configuration writes the same blocks to both drives and can run degraded with one member, consistent with a raid 1 mirrored disks.

C:

The array stripes data across disks without mirrored or parity redundancy, consistent with a raid 0 provides no disk fault tolerance.

Question 515

Two disks are striped for speed, and the loss of one member makes the entire volume unavailable. Which solution addresses the cause without unnecessary unrelated changes?

  1. Configure RAID 6 with supported controllers and enough healthy drives for two parity blocks
  2. Replace the failed member promptly, monitor the rebuild and maintain independent backups
  3. Configure supported RAID 1 and monitor rebuild and backup procedures
  4. Restore from a current backup and redesign with appropriate redundancy if uptime matters

Explanation

Correct Answer

D:

The array stripes data across disks without mirrored or parity redundancy, consistent with a raid 0 provides no disk fault tolerance.

Incorrect Answers

A:

The storage specification requires tolerance of any two failed members in the parity set, consistent with a raid 6 dual-parity design.

B:

The array can operate degraded after one disk failure but cannot tolerate a second concurrent member loss, consistent with a raid 5 single-parity tolerance.

C:

The configuration writes the same blocks to both drives and can run degraded with one member, consistent with a raid 1 mirrored disks.

Question 516

A two-drive workstation must keep identical copies of data on both drives and tolerate one drive failure. Which corrective action is the safest and most direct response?

  1. Configure RAID 6 with supported controllers and enough healthy drives for two parity blocks
  2. Replace the failed member promptly, monitor the rebuild and maintain independent backups
  3. Restore from a current backup and redesign with appropriate redundancy if uptime matters
  4. Configure supported RAID 1 and monitor rebuild and backup procedures

Explanation

Correct Answer

D:

The configuration writes the same blocks to both drives and can run degraded with one member, consistent with a raid 1 mirrored disks.

Incorrect Answers

A:

The storage specification requires tolerance of any two failed members in the parity set, consistent with a raid 6 dual-parity design.

B:

The array can operate degraded after one disk failure but cannot tolerate a second concurrent member loss, consistent with a raid 5 single-parity tolerance.

C:

The array stripes data across disks without mirrored or parity redundancy, consistent with a raid 0 provides no disk fault tolerance.

Question 517

A technician has authorization to fix the issue: A storage box has four equal drives in a RAID 5 array and one disk fails; reads continue but another failure during rebuild threatens data. What action should be taken next?

  1. Configure supported RAID 1 and monitor rebuild and backup procedures
  2. Replace the failed member promptly, monitor the rebuild and maintain independent backups
  3. Restore from a current backup and redesign with appropriate redundancy if uptime matters
  4. Configure RAID 6 with supported controllers and enough healthy drives for two parity blocks

Explanation

Correct Answer

B:

The array can operate degraded after one disk failure but cannot tolerate a second concurrent member loss, consistent with a raid 5 single-parity tolerance.

Incorrect Answers

A:

The configuration writes the same blocks to both drives and can run degraded with one member, consistent with a raid 1 mirrored disks.

C:

The array stripes data across disks without mirrored or parity redundancy, consistent with a raid 0 provides no disk fault tolerance.

D:

The storage specification requires tolerance of any two failed members in the parity set, consistent with a raid 6 dual-parity design.

Question 518

An archival server needs a parity array that can survive two simultaneous disk failures without a mirrored copy of every drive. Which repair or configuration change addresses the underlying problem?

  1. Configure RAID 10 using at least four drives and verify the supported failure combinations
  2. Configure supported RAID 1 and monitor rebuild and backup procedures
  3. Replace the failed member promptly, monitor the rebuild and maintain independent backups
  4. Configure RAID 6 with supported controllers and enough healthy drives for two parity blocks

Explanation

Correct Answer

D:

The storage specification requires tolerance of any two failed members in the parity set, consistent with a raid 6 dual-parity design.

Incorrect Answers

A:

The storage layout combines mirrors with striping across pairs rather than simple parity, consistent with a raid 10 striped mirrors.

B:

The configuration writes the same blocks to both drives and can run degraded with one member, consistent with a raid 1 mirrored disks.

C:

The array can operate degraded after one disk failure but cannot tolerate a second concurrent member loss, consistent with a raid 5 single-parity tolerance.

Question 519

A maintenance window is available for the following problem: A database server requires both mirrored redundancy and performance from a stripe built over multiple mirrored pairs. Which intervention is most appropriate?

  1. Choose a supported SAS HBA or drive compatible with the storage controller
  2. Configure RAID 6 with supported controllers and enough healthy drives for two parity blocks
  3. Configure RAID 10 using at least four drives and verify the supported failure combinations
  4. Configure supported RAID 1 and monitor rebuild and backup procedures

Explanation

Correct Answer

C:

The storage layout combines mirrors with striping across pairs rather than simple parity, consistent with a raid 10 striped mirrors.

Incorrect Answers

A:

The drive connector and controller specifications show SAS disks unsupported by the SATA-only host, consistent with a sas drive requires compatible controller interface.

B:

The storage specification requires tolerance of any two failed members in the parity set, consistent with a raid 6 dual-parity design.

D:

The configuration writes the same blocks to both drives and can run degraded with one member, consistent with a raid 1 mirrored disks.

Question 520

The owner wants a specific repair, not merely more monitoring: A business storage backplane uses enterprise SAS disks, while an off-the-shelf SATA-only controller cannot communicate with them. What should the technician do?

  1. Choose a supported SAS HBA or drive compatible with the storage controller
  2. Configure supported RAID 1 and monitor rebuild and backup procedures
  3. Configure RAID 10 using at least four drives and verify the supported failure combinations
  4. Use an M.2 SATA SSD supported by the slot or a platform offering NVMe

Explanation

Correct Answer

A:

The drive connector and controller specifications show SAS disks unsupported by the SATA-only host, consistent with a sas drive requires compatible controller interface.

Incorrect Answers

B:

The configuration writes the same blocks to both drives and can run degraded with one member, consistent with a raid 1 mirrored disks.

C:

The storage layout combines mirrors with striping across pairs rather than simple parity, consistent with a raid 10 striped mirrors.

D:

The device manual specifies SATA-based M.2 storage while the replacement requires PCIe NVMe, consistent with a m.2 physical form factor is not the storage protocol.

CompTIA A+ Certification Exam: Core 1 (220-1201) Practice Tests