Question 530 A gaming desktop's graphics card requires a separate auxiliary power connector and crashes as soon as 3D load increases. Which repair or configuration change addresses the underlying problem? Clean and reapply an appropriate thermal compound layer and reseat the cooler correctly Connect the correct PSU-provided PCIe power leads and verify capacity and routing Install in an appropriate compatible PCIe slot and ensure power and clearance Power down and reconnect the CPU cooler to the appropriate monitored header Explanation Correct Answer B:The GPU documentation requires a specific PCIe power plug and the connector is not attached, consistent with a missing gpu auxiliary pcie power connection. Incorrect Answers A:A properly spinning fan is present, but the heat spreader has dry or uneven thermal compound, consistent with an insufficient thermal interface between cpu and heatsink. C:The card has an x16 edge connector and a specified lane and chassis-space requirement, consistent with a pcie x16 slot requirement for common graphics cards. D:The CPU_FAN header is empty while the actual cooler lead is attached to SYS_FAN, consistent with a cpu cooling fan plugged into incorrect header.
Question 531 A maintenance window is available for the following problem: A motherboard reports CPU fan failure at startup even though a case fan is spinning; the processor cooler was plugged into a chassis-fan header. Which intervention is most appropriate? Clean and reapply an appropriate thermal compound layer and reseat the cooler correctly Power down and reconnect the CPU cooler to the appropriate monitored header Enable the approved CPU virtualization setting in UEFI and verify hypervisor detection Connect the front I/O cable to the specified matching header with power disconnected Explanation Correct Answer B:The CPU_FAN header is empty while the actual cooler lead is attached to SYS_FAN, consistent with a cpu cooling fan plugged into incorrect header. Incorrect Answers A:A properly spinning fan is present, but the heat spreader has dry or uneven thermal compound, consistent with an insufficient thermal interface between cpu and heatsink. C:Firmware reports the processor's virtualization feature as disabled despite compatible CPU specifications, consistent with a cpu virtualization extension disabled in firmware. D:The chassis front-panel cable and board manual identify different header pinouts, consistent with a motherboard internal header connection mismatch.
Question 532 The owner wants a specific repair, not merely more monitoring: A legacy desktop PSU has a manual voltage selector set to 115 V but the computer is moved to a 230 V mains supply. What should the technician do? Connect the proper ATX main power plug and verify any required CPU auxiliary power Size a quality PSU for actual sustained load, transient margin and needed connectors Use the new PSU manufacturer's approved modular cables and verify connectors Set the proper input if the unit supports manual switching, or replace it with an appropriate auto-ranging PSU Explanation Correct Answer D:The supply's rating label and selector position do not match the local AC voltage, consistent with an incorrect psu input voltage selection. Incorrect Answers A:The PSU main 20+4 pin connector is disconnected from the motherboard socket, consistent with a missing motherboard 24-pin atx power connection. B:Measured peak power and required PCIe power connectors exceed the PSU's continuous rating, consistent with an insufficient psu wattage and headroom. C:The new PSU's cable pinout is not confirmed compatible with the old modular cable set, consistent with an incompatible modular psu cable pinout risk.
Question 533 A motherboard receives standby power but never starts; the main board connector is unplugged even though drive power plugs are connected. Which solution addresses the cause without unnecessary unrelated changes? Use the new PSU manufacturer's approved modular cables and verify connectors Set the proper input if the unit supports manual switching, or replace it with an appropriate auto-ranging PSU Install and test supported redundant PSUs on independent power paths Connect the proper ATX main power plug and verify any required CPU auxiliary power Explanation Correct Answer D:The PSU main 20+4 pin connector is disconnected from the motherboard socket, consistent with a missing motherboard 24-pin atx power connection. Incorrect Answers A:The new PSU's cable pinout is not confirmed compatible with the old modular cable set, consistent with an incompatible modular psu cable pinout risk. B:The supply's rating label and selector position do not match the local AC voltage, consistent with an incorrect psu input voltage selection. C:The chassis supports two PSU modules and can remain powered with one module disconnected, consistent with a redundant hot-swappable power supply modules.
Question 534 A graphics workstation adds a second GPU and begins restarting when both GPUs reach high load because total demand exceeds the old supply. Which corrective action is the safest and most direct response? Size a quality PSU for actual sustained load, transient margin and needed connectors Set the proper input if the unit supports manual switching, or replace it with an appropriate auto-ranging PSU Use the new PSU manufacturer's approved modular cables and verify connectors Install and test supported redundant PSUs on independent power paths Explanation Correct Answer A:Measured peak power and required PCIe power connectors exceed the PSU's continuous rating, consistent with an insufficient psu wattage and headroom. Incorrect Answers B:The supply's rating label and selector position do not match the local AC voltage, consistent with an incorrect psu input voltage selection. C:The new PSU's cable pinout is not confirmed compatible with the old modular cable set, consistent with an incompatible modular psu cable pinout risk. D:The chassis supports two PSU modules and can remain powered with one module disconnected, consistent with a redundant hot-swappable power supply modules.
Question 535 A technician has authorization to fix the issue: A storage server must keep running when one power supply module fails and has two independent AC feeds. What action should be taken next? Size a quality PSU for actual sustained load, transient margin and needed connectors Install and test supported redundant PSUs on independent power paths Connect the proper ATX main power plug and verify any required CPU auxiliary power Choose adequate wattage first, then compare efficiency and cooling under expected loads Explanation Correct Answer B:The chassis supports two PSU modules and can remain powered with one module disconnected, consistent with a redundant hot-swappable power supply modules. Incorrect Answers A:Measured peak power and required PCIe power connectors exceed the PSU's continuous rating, consistent with an insufficient psu wattage and headroom. C:The PSU main 20+4 pin connector is disconnected from the motherboard socket, consistent with a missing motherboard 24-pin atx power connection. D:The efficiency rating measures input-to-output conversion losses, not the PSU's maximum continuous wattage, consistent with a power-supply efficiency versus rated output.
Question 536 A technician replaces a modular PSU but reuses old manufacturer-specific modular cables because the device-side plugs fit. Which repair or configuration change addresses the underlying problem? Connect the proper ATX main power plug and verify any required CPU auxiliary power Use the new PSU manufacturer's approved modular cables and verify connectors Size a quality PSU for actual sustained load, transient margin and needed connectors Set the proper input if the unit supports manual switching, or replace it with an appropriate auto-ranging PSU Explanation Correct Answer B:The new PSU's cable pinout is not confirmed compatible with the old modular cable set, consistent with an incompatible modular psu cable pinout risk. Incorrect Answers A:The PSU main 20+4 pin connector is disconnected from the motherboard socket, consistent with a missing motherboard 24-pin atx power connection. C:Measured peak power and required PCIe power connectors exceed the PSU's continuous rating, consistent with an insufficient psu wattage and headroom. D:The supply's rating label and selector position do not match the local AC voltage, consistent with an incorrect psu input voltage selection.
Question 537 A maintenance window is available for the following problem: Two otherwise similar supplies offer different 80 PLUS efficiency ratings; the buyer expects the higher rating to mean twice as much output power. Which intervention is most appropriate? Use the new PSU manufacturer's approved modular cables and verify connectors Install and test supported redundant PSUs on independent power paths Size a quality PSU for actual sustained load, transient margin and needed connectors Choose adequate wattage first, then compare efficiency and cooling under expected loads Explanation Correct Answer D:The efficiency rating measures input-to-output conversion losses, not the PSU's maximum continuous wattage, consistent with a power-supply efficiency versus rated output. Incorrect Answers A:The new PSU's cable pinout is not confirmed compatible with the old modular cable set, consistent with an incompatible modular psu cable pinout risk. B:The chassis supports two PSU modules and can remain powered with one module disconnected, consistent with a redundant hot-swappable power supply modules. C:Measured peak power and required PCIe power connectors exceed the PSU's continuous rating, consistent with an insufficient psu wattage and headroom.
Question 538 The owner wants a specific repair, not merely more monitoring: An accounting group prints PDFs with specialized vector graphics but the chosen printer driver renders unsupported page description commands as symbols. What should the technician do? Configure an approved SMTP relay and test a secured scan-to-email workflow Install the vendor-supported driver with the correct printer language and test the sample document Enable automatic duplex in the printer preferences and select correct binding orientation Enable secure release and suitable audit logging with controlled printer access Explanation Correct Answer B:A PCL/PostScript compatibility test identifies the incorrect driver language for the printer firmware, consistent with a printer page-description language and driver compatibility. Incorrect Answers A:The device can scan locally but has no valid SMTP relay credentials or allowed sender, consistent with a scan-to-email server configuration missing. C:The device and driver both support two-sided printing but the job preference is simplex, consistent with a duplex printing setting. D:The printer supports badge or PIN release and keeps jobs encrypted or queued until the user arrives, consistent with a secure print release with user authentication.
Question 539 A shared multifunction printer holds HR records and users want pages released only after they authenticate at the device. Which solution addresses the cause without unnecessary unrelated changes? Install the vendor-supported driver with the correct printer language and test the sample document Configure an approved SMTP relay and test a secured scan-to-email workflow Configure a supported print server share and appropriate printer driver deployment Enable secure release and suitable audit logging with controlled printer access Explanation Correct Answer D:The printer supports badge or PIN release and keeps jobs encrypted or queued until the user arrives, consistent with a secure print release with user authentication. Incorrect Answers A:A PCL/PostScript compatibility test identifies the incorrect driver language for the printer firmware, consistent with a printer page-description language and driver compatibility. B:The device can scan locally but has no valid SMTP relay credentials or allowed sender, consistent with a scan-to-email server configuration missing. C:The server publishes a controlled shared queue and clients submit jobs to that central endpoint, consistent with a central print server and shared queue.
Question 540 A branch office wants long reports printed on both sides of each sheet, but the default output uses single-sided pages. Which corrective action is the safest and most direct response? Configure a supported print server share and appropriate printer driver deployment Use a duplex-capable ADF or scan each side via a supported manual procedure Enable automatic duplex in the printer preferences and select correct binding orientation Enable secure release and suitable audit logging with controlled printer access Explanation Correct Answer C:The device and driver both support two-sided printing but the job preference is simplex, consistent with a duplex printing setting. Incorrect Answers A:The server publishes a controlled shared queue and clients submit jobs to that central endpoint, consistent with a central print server and shared queue. B:The available ADF supports simplex only while the requested workflow requires both sides, consistent with an automatic document feeder duplex scanning capability. D:The printer supports badge or PIN release and keeps jobs encrypted or queued until the user arrives, consistent with a secure print release with user authentication.