McAfee Secured

Exam Code: 220-1201

Exam Name: CompTIA A+ Certification Exam: Core 1

Certification Provider: CompTIA

Corresponding Certification: CompTIA A+

100% CompTIA 220-1201 Guaranteed Success With Testking Training Materials

Get Real 220-1201 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

527 Questions & Answers with Testing Engine

"CompTIA A+ Certification Exam: Core 1 Exam", also known as 220-1201 exam, is a CompTIA certification exam.

Pass your tests with the always up-to-date 220-1201 Exam Engine. Your 220-1201 training materials keep you at the head of the pack!

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Was: $137.49
Now: $124.99

CompTIA 220-1201 Practice Test 95

Question 940

A server's fan makes a grinding sound and CPU temperatures climb even when the case filters are clean. Which technical consequence or limitation best explains why the problem matters?

  1. Replacing storage drives cannot remove airflow restrictions causing thermal shutdowns
  2. Higher memory speed does not overcome a CPU held back by thermal protection
  3. A display cable replacement cannot correct processor initialization failure before video startup
  4. Additional software cooling policies cannot repair a physically failing fan bearing

Explanation

Correct Answer

D:

The fan rotor wobbles or intermittently stalls and its RPM falls below the specified minimum, consistent with a failing fan bearing in cooling assembly.

Incorrect Answers

A:

Fan speed rises while internal temperature continues increasing and dust blocks the intake, consistent with an overheating caused by obstructed airflow.

B:

CPU temperature and clock monitoring show thermal limits reached while the fan remains at low RPM, consistent with a firmware cooling policy causing cpu throttling.

C:

The motherboard beep code and CPU support list indicate the processor requires a newer supported BIOS, consistent with an unsupported cpu or firmware initialization failure.

Question 941

A user asks what may happen if the issue is not correctly handled: A PC powers up but gives a repeating POST beep sequence and no video after a technician installed a new CPU. Which outcome is best supported?

  1. Higher memory speed does not overcome a CPU held back by thermal protection
  2. A blank monitor is not proof that the computer itself failed to start
  3. Replacing a monitor will not resolve firmware reporting failed memory initialization
  4. A display cable replacement cannot correct processor initialization failure before video startup

Explanation

Correct Answer

D:

The motherboard beep code and CPU support list indicate the processor requires a newer supported BIOS, consistent with an unsupported cpu or firmware initialization failure.

Incorrect Answers

A:

CPU temperature and clock monitoring show thermal limits reached while the fan remains at low RPM, consistent with a firmware cooling policy causing cpu throttling.

B:

The active video signal comes from the discrete card while the monitor is connected to an inactive motherboard output, consistent with a display output routed to wrong graphics port.

C:

The motherboard's documented beep code identifies RAM and inspection finds a DIMM latch not fully closed, consistent with a memory module unseated after transport.

Question 942

An office machine is unusually slow and the CPU clock stays far below base frequency even at moderate load; the heatsink is secure but its fan profile is set nearly off. Which prediction follows from this particular failure mode?

  1. Higher memory speed does not overcome a CPU held back by thermal protection
  2. Additional software cooling policies cannot repair a physically failing fan bearing
  3. Adding RAM will not correct a processor that is overheating
  4. A display cable replacement cannot correct processor initialization failure before video startup

Explanation

Correct Answer

A:

CPU temperature and clock monitoring show thermal limits reached while the fan remains at low RPM, consistent with a firmware cooling policy causing cpu throttling.

Incorrect Answers

B:

The fan rotor wobbles or intermittently stalls and its RPM falls below the specified minimum, consistent with a failing fan bearing in cooling assembly.

C:

The heatsink fan is stopped and temperature climbs rapidly before the slowdown, consistent with a cpu thermal throttling from failed cooling.

D:

The motherboard beep code and CPU support list indicate the processor requires a newer supported BIOS, consistent with an unsupported cpu or firmware initialization failure.

Question 943

When documenting this incident, a technician notes: A kiosk shows a black screen only after moving to a new monitor, but boot beeps and network remote access show the OS is running. Which limitation is most directly relevant?

  1. A display cable replacement cannot correct processor initialization failure before video startup
  2. Changing only the display resolution cannot make an undersized supply deliver more power
  3. A blank monitor is not proof that the computer itself failed to start
  4. A PSU can fail during short power spikes even if average usage appears acceptable

Explanation

Correct Answer

C:

The active video signal comes from the discrete card while the monitor is connected to an inactive motherboard output, consistent with a display output routed to wrong graphics port.

Incorrect Answers

A:

The motherboard beep code and CPU support list indicate the processor requires a newer supported BIOS, consistent with an unsupported cpu or firmware initialization failure.

B:

The shutdown coincides with combined CPU and GPU power demand rather than rising component temperature, consistent with a power supply capacity inadequate under load.

D:

Restarts correlate with GPU load transients while thermals remain within safe limits, consistent with a power supply transient response or headroom shortfall.

Question 944

A desktop's hard drive makes repeated clicks at startup and file reads intermittently hang. Which risk or behavior would be expected if a superficially attractive but incorrect workaround were used?

  1. Continued operation without redundancy exposes the array to complete loss on the remaining disk
  2. Continued retries on a mechanically failing disk can reduce the chance of data recovery
  3. More CPU cores will not fix a saturated disk I/O subsystem
  4. A disk can be readable today while internal telemetry predicts imminent failure

Explanation

Correct Answer

B:

SMART and vendor diagnostics show increasing media or seek errors alongside audible clicking, consistent with a mechanical hdd read-head or actuator failure.

Incorrect Answers

A:

Array management identifies exactly one failed member and the other mirror disk is healthy, consistent with a raid mirror degraded with one surviving member.

C:

Queue depth and response time rise with backup traffic while disk health reports no failure, consistent with a storage iops contention under concurrent load.

D:

Health attributes exceed vendor-defined thresholds and the firmware marks the disk at risk, consistent with a smart-reported impending disk failure.

Question 945

In a post-repair discussion, the team reviews: A storage drive's SMART predictive failure warning appears even though its files are still accessible. Which technical implication should be highlighted?

  1. Continued retries on a mechanically failing disk can reduce the chance of data recovery
  2. Continued operation without redundancy exposes the array to complete loss on the remaining disk
  3. Initializing new arrays over existing members can destroy recoverable RAID metadata
  4. A disk can be readable today while internal telemetry predicts imminent failure

Explanation

Correct Answer

D:

Health attributes exceed vendor-defined thresholds and the firmware marks the disk at risk, consistent with a smart-reported impending disk failure.

Incorrect Answers

A:

SMART and vendor diagnostics show increasing media or seek errors alongside audible clicking, consistent with a mechanical hdd read-head or actuator failure.

B:

Array management identifies exactly one failed member and the other mirror disk is healthy, consistent with a raid mirror degraded with one surviving member.

C:

The replacement controller has not imported the existing array metadata and lists members as foreign, consistent with a controller raid metadata or configuration mismatch.

Question 946

A freshly imaged PC displays 'no bootable device' after its boot-order settings were reset, though the SSD is detected in UEFI. Which technical consequence or limitation best explains why the problem matters?

  1. A full SSD can show slow sustained writes without mechanical failure sounds
  2. An SSD may be healthy while firmware searches the wrong boot destination
  3. A disk can be readable today while internal telemetry predicts imminent failure
  4. Repartitioning a drive that the installer cannot enumerate does not solve controller detection

Explanation

Correct Answer

B:

Firmware lists the SSD but selects a nonexistent network or USB boot target first, consistent with a boot order points away from installed os.

Incorrect Answers

A:

Sustained write benchmarks improve when adequate spare capacity and TRIM operation are restored, consistent with a ssd performance degradation under exhausted free space.

C:

Health attributes exceed vendor-defined thresholds and the firmware marks the disk at risk, consistent with a smart-reported impending disk failure.

D:

The installer sees no disk until the supported RAID/VMD controller driver is supplied, consistent with a missing storage controller driver or incompatible mode.

Question 947

A user asks what may happen if the issue is not correctly handled: A RAID 1 storage pair reports a degraded status after one drive was physically removed, but the shared folder remains online. Which outcome is best supported?

  1. A disk can be readable today while internal telemetry predicts imminent failure
  2. Continued operation without redundancy exposes the array to complete loss on the remaining disk
  3. Initializing new arrays over existing members can destroy recoverable RAID metadata
  4. More CPU cores will not fix a saturated disk I/O subsystem

Explanation

Correct Answer

B:

Array management identifies exactly one failed member and the other mirror disk is healthy, consistent with a raid mirror degraded with one surviving member.

Incorrect Answers

A:

Health attributes exceed vendor-defined thresholds and the firmware marks the disk at risk, consistent with a smart-reported impending disk failure.

C:

The replacement controller has not imported the existing array metadata and lists members as foreign, consistent with a controller raid metadata or configuration mismatch.

D:

Queue depth and response time rise with backup traffic while disk health reports no failure, consistent with a storage iops contention under concurrent load.

Question 948

After a storage controller replacement, a multi-disk RAID set appears as several unconfigured disks although the drives themselves pass health checks. Which prediction follows from this particular failure mode?

  1. Initializing new arrays over existing members can destroy recoverable RAID metadata
  2. Continued operation without redundancy exposes the array to complete loss on the remaining disk
  3. A disk can be readable today while internal telemetry predicts imminent failure
  4. Repartitioning a drive that the installer cannot enumerate does not solve controller detection

Explanation

Correct Answer

A:

The replacement controller has not imported the existing array metadata and lists members as foreign, consistent with a controller raid metadata or configuration mismatch.

Incorrect Answers

B:

Array management identifies exactly one failed member and the other mirror disk is healthy, consistent with a raid mirror degraded with one surviving member.

C:

Health attributes exceed vendor-defined thresholds and the firmware marks the disk at risk, consistent with a smart-reported impending disk failure.

D:

The installer sees no disk until the supported RAID/VMD controller driver is supplied, consistent with a missing storage controller driver or incompatible mode.

Question 949

When documenting this incident, a technician notes: A virtual host's storage remains online but latency spikes during backup windows and monitoring shows near-saturated read/write queues. Which limitation is most directly relevant?

  1. Continued operation without redundancy exposes the array to complete loss on the remaining disk
  2. More CPU cores will not fix a saturated disk I/O subsystem
  3. Repartitioning a drive that the installer cannot enumerate does not solve controller detection
  4. Initializing new arrays over existing members can destroy recoverable RAID metadata

Explanation

Correct Answer

B:

Queue depth and response time rise with backup traffic while disk health reports no failure, consistent with a storage iops contention under concurrent load.

Incorrect Answers

A:

Array management identifies exactly one failed member and the other mirror disk is healthy, consistent with a raid mirror degraded with one surviving member.

C:

The installer sees no disk until the supported RAID/VMD controller driver is supplied, consistent with a missing storage controller driver or incompatible mode.

D:

The replacement controller has not imported the existing array metadata and lists members as foreign, consistent with a controller raid metadata or configuration mismatch.

Question 950

A user copies a project to a removable USB drive, and files become corrupt only when the cable is touched. Which risk or behavior would be expected if a superficially attractive but incorrect workaround were used?

  1. A disk can be readable today while internal telemetry predicts imminent failure
  2. Reformatting repeatedly cannot repair an intermittent physical connection
  3. Continued operation without redundancy exposes the array to complete loss on the remaining disk
  4. A running disk motor proves power delivery, not a functional data link

Explanation

Correct Answer

B:

I/O errors correlate with movement and disappear with a known-good cable and port, consistent with an intermittent external drive cable or connector.

Incorrect Answers

A:

Health attributes exceed vendor-defined thresholds and the firmware marks the disk at risk, consistent with a smart-reported impending disk failure.

C:

Array management identifies exactly one failed member and the other mirror disk is healthy, consistent with a raid mirror degraded with one surviving member.

D:

The drive's power lead is connected but the SATA data cable is loose or fails a known-good swap, consistent with a disconnected or defective sata data path.

CompTIA A+ Certification Exam: Core 1 (220-1201) Practice Tests