McAfee Secured

Exam Code: 220-1201

Exam Name: CompTIA A+ Certification Exam: Core 1

Certification Provider: CompTIA

Corresponding Certification: CompTIA A+

100% CompTIA 220-1201 Guaranteed Success With Testking Training Materials

Get Real 220-1201 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

527 Questions & Answers with Testing Engine

"CompTIA A+ Certification Exam: Core 1 Exam", also known as 220-1201 exam, is a CompTIA certification exam.

Pass your tests with the always up-to-date 220-1201 Exam Engine. Your 220-1201 training materials keep you at the head of the pack!

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Was: $137.49
Now: $124.99

CompTIA 220-1201 Practice Test 38

Question 370

During a support incident, A conference room needs an LCD whose backlight can dim small areas for high dynamic range rather than one uniform brightness plane. What is the most likely technical explanation?

  1. Backlit LCD cannot turn off individual pixels
  2. Higher pixel density at fixed screen size
  3. Mini-LED local dimming backlight
  4. VA LCD alignment emphasizes contrast

Explanation

Correct Answer

C:

The display uses many small independently controlled backlight zones behind an LCD layer, consistent with a mini-led local dimming backlight.

Incorrect Answers

A:

Dark test patterns reveal illumination from the panel backlight despite black picture values, consistent with a backlit lcd cannot turn off individual pixels.

B:

The higher-resolution panel contains more addressable pixels across the same diagonal dimension, consistent with a higher pixel density at fixed screen size.

D:

The panel specification identifies vertical-alignment liquid crystals with strong native black-level contrast, consistent with a va lcd alignment emphasizes contrast.

Question 371

A designer compares two screens of equal physical size and notices one makes fine text sharper because it has more pixels per inch. Which failure mode should the technician prioritize?

  1. Mini-LED local dimming backlight
  2. Refresh-rate and synchronization mismatch
  3. Backlit LCD cannot turn off individual pixels
  4. Higher pixel density at fixed screen size

Explanation

Correct Answer

D:

The higher-resolution panel contains more addressable pixels across the same diagonal dimension, consistent with a higher pixel density at fixed screen size.

Incorrect Answers

A:

The display uses many small independently controlled backlight zones behind an LCD layer, consistent with a mini-led local dimming backlight.

B:

The GPU output frame rate is not synchronized with the display's active refresh mode, consistent with a refresh-rate and synchronization mismatch.

C:

Dark test patterns reveal illumination from the panel backlight despite black picture values, consistent with a backlit lcd cannot turn off individual pixels.

Question 372

A help-desk ticket states: A building crew must route Ethernet above a drop ceiling used to circulate environmental air, where fire code requires low-smoke cable jackets. Which diagnosis is best supported rather than simply possible?

  1. Outdoor direct-burial-rated copper cable
  2. Shielded twisted-pair cable for an EMI-prone route
  3. Single-mode fiber for a long-distance link
  4. Plenum-rated network cabling

Explanation

Correct Answer

D:

The installation path is an air-handling plenum and the cable jacket is rated for that occupancy, consistent with a plenum-rated network cabling.

Incorrect Answers

A:

The cable route lies underground and the selected cable jacket lacks water-blocking direct-burial construction, consistent with an outdoor direct-burial-rated copper cable.

B:

Signal errors correlate with motor operation and the proposed cable has foil or braid shielding, consistent with a shielded twisted-pair cable for an emi-prone route.

C:

The optics specify single-mode wavelength and use a small-core single-mode cable, consistent with a single-mode fiber for a long-distance link.

Question 373

When comparing several hypotheses, a technician observes: A network run shares a cable tray with motors and experiences induced electrical noise on unshielded twisted pairs. Which condition best fits?

  1. Digital HDMI-to-DisplayPort conversion compatibility
  2. Single-mode fiber for a long-distance link
  3. Shielded twisted-pair cable for an EMI-prone route
  4. Plenum-rated network cabling

Explanation

Correct Answer

C:

Signal errors correlate with motor operation and the proposed cable has foil or braid shielding, consistent with a shielded twisted-pair cable for an emi-prone route.

Incorrect Answers

A:

The endpoints expose different digital video interfaces and conversion direction matters, consistent with a digital hdmi-to-displayport conversion compatibility.

B:

The optics specify single-mode wavelength and use a small-core single-mode cable, consistent with a single-mode fiber for a long-distance link.

D:

The installation path is an air-handling plenum and the cable jacket is rated for that occupancy, consistent with a plenum-rated network cabling.

Question 374

A technician investigates this device problem: A campus needs a long fiber run between distant buildings with optics rated for a narrow-core light path. Which diagnosis best explains the observed pattern?

  1. Shielded twisted-pair cable for an EMI-prone route
  2. Single-mode fiber for a long-distance link
  3. USB link negotiated at the lowest supported hop
  4. Multimode fiber for a short optical link

Explanation

Correct Answer

B:

The optics specify single-mode wavelength and use a small-core single-mode cable, consistent with a single-mode fiber for a long-distance link.

Incorrect Answers

A:

Signal errors correlate with motor operation and the proposed cable has foil or braid shielding, consistent with a shielded twisted-pair cable for an emi-prone route.

C:

The device and host support USB 3.x but the intermediate hub reports USB 2.0 capabilities, consistent with a usb link negotiated at the lowest supported hop.

D:

The modules specify multimode short-reach optics and matching fiber type, consistent with a multimode fiber for a short optical link.

Question 375

A short datacenter optical link is specified with multimode SR transceivers and cost-effective larger-core fiber. Which underlying component or configuration issue is most consistent with the evidence?

  1. Single-mode fiber for a long-distance link
  2. USB link negotiated at the lowest supported hop
  3. LC small-form-factor optical connector
  4. Multimode fiber for a short optical link

Explanation

Correct Answer

D:

The modules specify multimode short-reach optics and matching fiber type, consistent with a multimode fiber for a short optical link.

Incorrect Answers

A:

The optics specify single-mode wavelength and use a small-core single-mode cable, consistent with a single-mode fiber for a long-distance link.

B:

The device and host support USB 3.x but the intermediate hub reports USB 2.0 capabilities, consistent with a usb link negotiated at the lowest supported hop.

C:

The switch transceiver has two small LC receptacles and the patch lead currently ends in SC plugs, consistent with a lc small-form-factor optical connector.

Question 376

During a support incident, A technician must attach a modern high-density fiber patch cord to LC ports on a switch rather than older larger SC sockets. What is the most likely technical explanation?

  1. LC small-form-factor optical connector
  2. RJ11 telephone and RJ45 Ethernet connector difference
  3. Single-mode fiber for a long-distance link
  4. Multimode fiber for a short optical link

Explanation

Correct Answer

A:

The switch transceiver has two small LC receptacles and the patch lead currently ends in SC plugs, consistent with a lc small-form-factor optical connector.

Incorrect Answers

B:

The telephone plug is narrower and uses fewer positions than the structured Ethernet connector, consistent with a rj11 telephone and rj45 ethernet connector difference.

C:

The optics specify single-mode wavelength and use a small-core single-mode cable, consistent with a single-mode fiber for a long-distance link.

D:

The modules specify multimode short-reach optics and matching fiber type, consistent with a multimode fiber for a short optical link.

Question 377

A user has a digital monitor with DisplayPort and a workstation with only HDMI; a VGA cable is available but loses the required digital signal characteristics. Which failure mode should the technician prioritize?

  1. Passive DisplayPort++ adapter used in the wrong direction
  2. Digital HDMI-to-DisplayPort conversion compatibility
  3. Insufficient video bandwidth for selected resolution
  4. Monitor input-source mismatch

Explanation

Correct Answer

B:

The endpoints expose different digital video interfaces and conversion direction matters, consistent with a digital hdmi-to-displayport conversion compatibility.

Incorrect Answers

A:

The passive adapter supports DP source to HDMI display, not an HDMI source to DP monitor, consistent with a passive displayport++ adapter used in the wrong direction.

C:

The link works at lower resolution but loses signal when switched to the highest output rate, consistent with an insufficient video bandwidth for selected resolution.

D:

A known-good DP signal reaches the display but the monitor is configured to listen to a different port, consistent with a monitor input-source mismatch.

Question 378

A help-desk ticket states: A USB peripheral can run at SuperSpeed on one port but only at USB 2.0 rates on an old hub between it and the PC. Which diagnosis is best supported rather than simply possible?

  1. Digital HDMI-to-DisplayPort conversion compatibility
  2. Outdoor direct-burial-rated copper cable
  3. Single-mode fiber for a long-distance link
  4. USB link negotiated at the lowest supported hop

Explanation

Correct Answer

D:

The device and host support USB 3.x but the intermediate hub reports USB 2.0 capabilities, consistent with a usb link negotiated at the lowest supported hop.

Incorrect Answers

A:

The endpoints expose different digital video interfaces and conversion direction matters, consistent with a digital hdmi-to-displayport conversion compatibility.

B:

The cable route lies underground and the selected cable jacket lacks water-blocking direct-burial construction, consistent with an outdoor direct-burial-rated copper cable.

C:

The optics specify single-mode wavelength and use a small-core single-mode cable, consistent with a single-mode fiber for a long-distance link.

Question 379

When comparing several hypotheses, a technician observes: A field network cable is buried directly between outdoor enclosures, but ordinary indoor cable has absorbed moisture and failed. Which condition best fits?

  1. Single-mode fiber for a long-distance link
  2. Digital HDMI-to-DisplayPort conversion compatibility
  3. Outdoor direct-burial-rated copper cable
  4. USB link negotiated at the lowest supported hop

Explanation

Correct Answer

C:

The cable route lies underground and the selected cable jacket lacks water-blocking direct-burial construction, consistent with an outdoor direct-burial-rated copper cable.

Incorrect Answers

A:

The optics specify single-mode wavelength and use a small-core single-mode cable, consistent with a single-mode fiber for a long-distance link.

B:

The endpoints expose different digital video interfaces and conversion direction matters, consistent with a digital hdmi-to-displayport conversion compatibility.

D:

The device and host support USB 3.x but the intermediate hub reports USB 2.0 capabilities, consistent with a usb link negotiated at the lowest supported hop.

Question 380

A technician investigates this device problem: A technician connects a four-position telephone line to an eight-position Ethernet jack and assumes the connectors are interchangeable. Which diagnosis best explains the observed pattern?

  1. RJ11 telephone and RJ45 Ethernet connector difference
  2. Outdoor direct-burial-rated copper cable
  3. Plenum-rated network cabling
  4. LC small-form-factor optical connector

Explanation

Correct Answer

A:

The telephone plug is narrower and uses fewer positions than the structured Ethernet connector, consistent with a rj11 telephone and rj45 ethernet connector difference.

Incorrect Answers

B:

The cable route lies underground and the selected cable jacket lacks water-blocking direct-burial construction, consistent with an outdoor direct-burial-rated copper cable.

C:

The installation path is an air-handling plenum and the cable jacket is rated for that occupancy, consistent with a plenum-rated network cabling.

D:

The switch transceiver has two small LC receptacles and the patch lead currently ends in SC plugs, consistent with a lc small-form-factor optical connector.

CompTIA A+ Certification Exam: Core 1 (220-1201) Practice Tests