McAfee Secured

Exam Code: NSE5_FSW_AD-7.6

Exam Name: Fortinet NSE 5 - FortiSwitch 7.6 Administrator

Certification Provider: Fortinet

Corresponding Certification: NSE5

100% Fortinet NSE5_FSW_AD-7.6 Guaranteed Success With Testking Training Materials

Get Real NSE5_FSW_AD-7.6 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

64 Questions & Answers with Testing Engine

"Fortinet NSE 5 - FortiSwitch 7.6 Administrator Exam", also known as NSE5_FSW_AD-7.6 exam, is a Fortinet certification exam.

Pass your tests with the always up-to-date NSE5_FSW_AD-7.6 Exam Engine. Your NSE5_FSW_AD-7.6 training materials keep you at the head of the pack!

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Was: $137.49
Now: $124.99

Fortinet NSE5_FSW_AD-7.6 Practice Test 2

Question 10

An uplink between two FortiSwitch units carries the default VLAN but drops tagged voice VLAN 230 at the second switch. What network mechanism best accounts for this failure?

  1. FortiGate VDOM separation governs administrative scope as well as segmentation; global administration is not required for routine tenant-specific changes.
  2. Policy matching depends on direction and exact flow fields; a correct business intention can still be enforced on the wrong traffic.
  3. Tagged frames are forwarded through a FortiSwitch trunk only when the VLAN tag is permitted by the configured memberships at each hop.
  4. FortiSwitch classifies incoming untagged Ethernet frames using the port's native VLAN; changing an unrelated tagged list does not correct the untagged ingress classification.

Explanation

Correct Answer

C:

Tagged frames are forwarded through a FortiSwitch trunk only when the VLAN tag is permitted by the configured memberships at each hop. It explains why this specific change is appropriate: Add the required tagged VLAN to the allowed VLAN lists on both ends of the appropriate uplink, preserving native VLAN intent. The result can be checked by: Capture or trace tagged traffic across the uplink and confirm the destination switch learns the correct VLAN membership.

Other Answers

A:

FortiGate VDOM separation governs administrative scope as well as segmentation; global administration is not required for routine tenant-specific changes. The cause in the stated scenario is different: Tagged frames are forwarded through a FortiSwitch trunk only when the VLAN tag is permitted by the configured memberships at each hop.

B:

Policy matching depends on direction and exact flow fields; a correct business intention can still be enforced on the wrong traffic. The cause in the stated scenario is different: Tagged frames are forwarded through a FortiSwitch trunk only when the VLAN tag is permitted by the configured memberships at each hop.

D:

FortiSwitch classifies incoming untagged Ethernet frames using the port's native VLAN; changing an unrelated tagged list does not correct the untagged ingress classification. The cause in the stated scenario is different: Tagged frames are forwarded through a FortiSwitch trunk only when the VLAN tag is permitted by the configured memberships at each hop.

Question 11

An uplink between two FortiSwitch units carries the default VLAN but drops tagged voice VLAN 230 at the second switch. What should the administrator measure to demonstrate the change works?

  1. Capture or trace tagged traffic across the uplink and confirm the destination switch learns the correct VLAN membership.
  2. Compare effective tenant port policies and run negative isolation tests after a staged profile deployment.
  3. Test access to allowed sensor services and denied staff resources from the reassigned port.
  4. Test the permitted application and an intentionally disallowed flow in both directions after applying a narrowly scoped correction.

Explanation

Correct Answer

A:

Capture or trace tagged traffic across the uplink and confirm the destination switch learns the correct VLAN membership. This checks the outcome of the selected action: Add the required tagged VLAN to the allowed VLAN lists on both ends of the appropriate uplink, preserving native VLAN intent. The relevant network behavior is: Tagged frames are forwarded through a FortiSwitch trunk only when the VLAN tag is permitted by the configured memberships at each hop.

Other Answers

B:

Compare effective tenant port policies and run negative isolation tests after a staged profile deployment. This could confirm success where a regional provider duplicates a VDOM switch configuration without updating the tenant-specific allowed VLAN list. The requested condition should instead be verified by: Capture or trace tagged traffic across the uplink and confirm the destination switch learns the correct VLAN membership.

C:

Test access to allowed sensor services and denied staff resources from the reassigned port. That test would be valuable for a different deployment: A contractor device should use a restricted VLAN, but an administrative change gives it the trusted staff VLAN without any identity review. For the current scenario it does not validate the targeted fix; the necessary evidence is: Capture or trace tagged traffic across the uplink and confirm the destination switch learns the correct VLAN membership.

D:

Test the permitted application and an intentionally disallowed flow in both directions after applying a narrowly scoped correction. This could confirm success where a port ACL denies an approved application because the source and destination fields were reversed in the intended access rule. The requested condition should instead be verified by: Capture or trace tagged traffic across the uplink and confirm the destination switch learns the correct VLAN membership.

Question 12

An uplink between two FortiSwitch units carries the default VLAN but drops tagged voice VLAN 230 at the second switch. Which preventive policy best addresses the same failure mode?

  1. Enforce least-privilege administrator profiles and periodic tenant entitlement reviews.
  2. Document gateway placement and firewall policy alongside every VLAN rollout to avoid accidental Layer 2 bridging.
  3. Maintain matching trunk-allowed VLAN inventories and test each new VLAN end to end before handover.
  4. Require port-owner approval, segmentation inventory, and negative reachability tests for VLAN reassignment.

Explanation

Correct Answer

C:

Maintain matching trunk-allowed VLAN inventories and test each new VLAN end to end before handover. This guards against recurrence because Tagged frames are forwarded through a FortiSwitch trunk only when the VLAN tag is permitted by the configured memberships at each hop.

Other Answers

A:

Enforce least-privilege administrator profiles and periodic tenant entitlement reviews. That guardrail is most relevant when an outsourced operator needs to manage only one customer's FortiSwitch ports but is granted global FortiGate administrative privileges. It would not reliably prevent the stated problem. The direct preventive control is: Maintain matching trunk-allowed VLAN inventories and test each new VLAN end to end before handover.

B:

Document gateway placement and firewall policy alongside every VLAN rollout to avoid accidental Layer 2 bridging. That preventive measure addresses another exposure: A retail deployment requires guest isolation, yet its engineers plan to bridge the guest VLAN into the employee broadcast domain to restore Internet access. This scenario requires the following control to reduce recurrence: Maintain matching trunk-allowed VLAN inventories and test each new VLAN end to end before handover.

D:

Require port-owner approval, segmentation inventory, and negative reachability tests for VLAN reassignment. That preventive measure addresses another exposure: A factory sensor is connected to a formerly trusted port and starts reaching systems outside its approved segment. This scenario requires the following control to reduce recurrence: Maintain matching trunk-allowed VLAN inventories and test each new VLAN end to end before handover.

Question 13

An added building-security VLAN is locally configured yet disappears on the trunk toward the distribution switch. Which configuration or design adjustment best meets the requirement?

  1. Inspect the allowed VLAN configuration for the ingress and egress ports and admit only the intended VLAN tag.
  2. Keep the VLANs logically separate and implement approved Layer 3 interfaces, policies, and routing for permitted cross-segment traffic.
  3. Restore the restricted port VLAN and validate that the security policy blocks unapproved destinations.
  4. Add the required tagged VLAN to the allowed VLAN lists on both ends of the appropriate uplink, preserving native VLAN intent.

Explanation

Correct Answer

D:

Tagged frames are forwarded through a FortiSwitch trunk only when the VLAN tag is permitted by the configured memberships at each hop. To validate the correction: Capture or trace tagged traffic across the uplink and confirm the destination switch learns the correct VLAN membership.

Other Answers

A:

A physically active switch trunk can still discard frames whose VLAN identifiers are not included in the approved tagged forwarding list. It does not resolve the specific failure; the targeted correction is: Add the required tagged VLAN to the allowed VLAN lists on both ends of the appropriate uplink, preserving native VLAN intent.

B:

Keep the VLANs logically separate and implement approved Layer 3 interfaces, policies, and routing for permitted cross-segment traffic. This is a reasonable response when two business segments are expected to communicate across a FortiGate boundary, but operators try to fix the separation by enabling every VLAN on the switch uplink. It does not target the current root cause: Tagged frames are forwarded through a FortiSwitch trunk only when the VLAN tag is permitted by the configured memberships at each hop.

C:

FortiSwitch VLAN assignment governs the initial Layer 2 segment; access control still requires policy at any permitted Layer 3 boundary. It does not resolve the specific failure; the targeted correction is: Add the required tagged VLAN to the allowed VLAN lists on both ends of the appropriate uplink, preserving native VLAN intent.

Question 14

An added building-security VLAN is locally configured yet disappears on the trunk toward the distribution switch. What network mechanism best accounts for this failure?

  1. Security orchestration requires an effective switch role or VLAN change; a detection event alone does not disconnect a device.
  2. Multi-tenancy segmentation does not automatically prevent overprivileged management-plane actions from crossing tenant boundaries.
  3. FortiSwitch VLAN assignment governs the initial Layer 2 segment; access control still requires policy at any permitted Layer 3 boundary.
  4. Tagged frames are forwarded through a FortiSwitch trunk only when the VLAN tag is permitted by the configured memberships at each hop.

Explanation

Correct Answer

D:

Tagged frames are forwarded through a FortiSwitch trunk only when the VLAN tag is permitted by the configured memberships at each hop. It explains why this specific change is appropriate: Add the required tagged VLAN to the allowed VLAN lists on both ends of the appropriate uplink, preserving native VLAN intent. The result can be checked by: Capture or trace tagged traffic across the uplink and confirm the destination switch learns the correct VLAN membership.

Other Answers

A:

Security orchestration requires an effective switch role or VLAN change; a detection event alone does not disconnect a device. The cause in the stated scenario is different: Tagged frames are forwarded through a FortiSwitch trunk only when the VLAN tag is permitted by the configured memberships at each hop.

B:

Multi-tenancy segmentation does not automatically prevent overprivileged management-plane actions from crossing tenant boundaries. The cause in the stated scenario is different: Tagged frames are forwarded through a FortiSwitch trunk only when the VLAN tag is permitted by the configured memberships at each hop.

C:

FortiSwitch VLAN assignment governs the initial Layer 2 segment; access control still requires policy at any permitted Layer 3 boundary. The cause in the stated scenario is different: Tagged frames are forwarded through a FortiSwitch trunk only when the VLAN tag is permitted by the configured memberships at each hop.

Question 15

An added building-security VLAN is locally configured yet disappears on the trunk toward the distribution switch. What should the administrator measure to demonstrate the change works?

  1. Capture or trace tagged traffic across the uplink and confirm the destination switch learns the correct VLAN membership.
  2. Confirm that test traffic traverses the intended policy boundary and produces the expected security event or denial.
  3. Test approved tags and an unauthorized management VLAN tag; confirm the latter is filtered at the boundary.
  4. Check the managed port configuration and confirm the client is learned in the intended VLAN after reconnecting.

Explanation

Correct Answer

A:

Capture or trace tagged traffic across the uplink and confirm the destination switch learns the correct VLAN membership. This checks the outcome of the selected action: Add the required tagged VLAN to the allowed VLAN lists on both ends of the appropriate uplink, preserving native VLAN intent. The relevant network behavior is: Tagged frames are forwarded through a FortiSwitch trunk only when the VLAN tag is permitted by the configured memberships at each hop.

Other Answers

B:

Confirm that test traffic traverses the intended policy boundary and produces the expected security event or denial. This could confirm success where an administrator assumes placing two hosts in distinct VLAN names invokes FortiGate threat inspection even when their traffic never crosses it. The requested condition should instead be verified by: Capture or trace tagged traffic across the uplink and confirm the destination switch learns the correct VLAN membership.

C:

Test approved tags and an unauthorized management VLAN tag; confirm the latter is filtered at the boundary. That test would be valuable for a different deployment: A shared switch trunk allows a VLAN containing management interfaces to traverse an uplink where only user services should be present. For the current scenario it does not validate the targeted fix; the necessary evidence is: Capture or trace tagged traffic across the uplink and confirm the destination switch learns the correct VLAN membership.

D:

Check the managed port configuration and confirm the client is learned in the intended VLAN after reconnecting. This could confirm success where a FortiLink-managed switch has an approved user VLAN but one access port inherits a different native VLAN from an earlier template. The requested condition should instead be verified by: Capture or trace tagged traffic across the uplink and confirm the destination switch learns the correct VLAN membership.

Question 16

An added building-security VLAN is locally configured yet disappears on the trunk toward the distribution switch. What change to the implementation checklist would reduce this specific risk?

  1. Map each threat to the correct Layer 2, routed firewall, or application inspection control in security designs.
  2. Require port-owner approval, segmentation inventory, and negative reachability tests for VLAN reassignment.
  3. Maintain matching trunk-allowed VLAN inventories and test each new VLAN end to end before handover.
  4. Review routing and policy reachability whenever a new FortiSwitch VLAN is introduced.

Explanation

Correct Answer

C:

Maintain matching trunk-allowed VLAN inventories and test each new VLAN end to end before handover. This guards against recurrence because Tagged frames are forwarded through a FortiSwitch trunk only when the VLAN tag is permitted by the configured memberships at each hop.

Other Answers

A:

Map each threat to the correct Layer 2, routed firewall, or application inspection control in security designs. That guardrail is most relevant when a campus reacts to DHCP spoofing by increasing application-layer web filtering while leaving untrusted DHCP replies unrestricted. It would not reliably prevent the stated problem. The direct preventive control is: Maintain matching trunk-allowed VLAN inventories and test each new VLAN end to end before handover.

B:

Require port-owner approval, segmentation inventory, and negative reachability tests for VLAN reassignment. That preventive measure addresses another exposure: A contractor device should use a restricted VLAN, but an administrative change gives it the trusted staff VLAN without any identity review. This scenario requires the following control to reduce recurrence: Maintain matching trunk-allowed VLAN inventories and test each new VLAN end to end before handover.

D:

Review routing and policy reachability whenever a new FortiSwitch VLAN is introduced. That preventive measure addresses another exposure: Clients in two VLANs can reach their own gateways but inter-VLAN applications are blocked despite switch port links being healthy. This scenario requires the following control to reduce recurrence: Maintain matching trunk-allowed VLAN inventories and test each new VLAN end to end before handover.

Question 17

A switch receives tagged VLAN 120 traffic on an uplink where only VLAN 130 is admitted, and the host cannot reach its gateway. Which configuration or design adjustment best meets the requirement?

  1. Check the FortiSwitch model's supported transceiver matrix, optical specifications, and link diagnostics before changing VLAN settings.
  2. Restore the restricted port VLAN and validate that the security policy blocks unapproved destinations.
  3. Inspect the allowed VLAN configuration for the ingress and egress ports and admit only the intended VLAN tag.
  4. Review and specialize each tenant's profile before applying changes to shared switch ports or uplinks.

Explanation

Correct Answer

C:

A physically active switch trunk can still discard frames whose VLAN identifiers are not included in the approved tagged forwarding list. To validate the correction: Use per-port VLAN configuration and a controlled tagged test to show that allowed frames forward while an unapproved tag stays blocked.

Other Answers

A:

A connector fitting the cage does not prove the optic is supported or the optical link budget and speed match. It does not resolve the specific failure; the targeted correction is: Inspect the allowed VLAN configuration for the ingress and egress ports and admit only the intended VLAN tag.

B:

Restore the restricted port VLAN and validate that the security policy blocks unapproved destinations. This is a reasonable response when a contractor device should use a restricted VLAN, but an administrative change gives it the trusted staff VLAN without any identity review. It does not target the current root cause: A physically active switch trunk can still discard frames whose VLAN identifiers are not included in the approved tagged forwarding list.

D:

Review and specialize each tenant's profile before applying changes to shared switch ports or uplinks. This is a reasonable response when a regional provider duplicates a VDOM switch configuration without updating the tenant-specific allowed VLAN list. It does not target the current root cause: A physically active switch trunk can still discard frames whose VLAN identifiers are not included in the approved tagged forwarding list.

Question 18

A switch receives tagged VLAN 120 traffic on an uplink where only VLAN 130 is admitted, and the host cannot reach its gateway. Why is the described behavior occurring?

  1. VLANs create separate Layer 2 broadcast domains; an allowed trunk tag does not replace inter-VLAN routing or security policy enforcement.
  2. A physically active switch trunk can still discard frames whose VLAN identifiers are not included in the approved tagged forwarding list.
  3. Creating a VLAN object on the FortiGate does not automatically assign every FortiSwitch access port to that VLAN.
  4. Multi-tenancy requires explicit mapping between shared physical switching resources and FortiGate virtual domains; port sharing alone does not provide isolation.

Explanation

Correct Answer

B:

A physically active switch trunk can still discard frames whose VLAN identifiers are not included in the approved tagged forwarding list. It explains why this specific change is appropriate: Inspect the allowed VLAN configuration for the ingress and egress ports and admit only the intended VLAN tag. The result can be checked by: Use per-port VLAN configuration and a controlled tagged test to show that allowed frames forward while an unapproved tag stays blocked.

Other Answers

A:

VLANs create separate Layer 2 broadcast domains; an allowed trunk tag does not replace inter-VLAN routing or security policy enforcement. The cause in the stated scenario is different: A physically active switch trunk can still discard frames whose VLAN identifiers are not included in the approved tagged forwarding list.

C:

Creating a VLAN object on the FortiGate does not automatically assign every FortiSwitch access port to that VLAN. The cause in the stated scenario is different: A physically active switch trunk can still discard frames whose VLAN identifiers are not included in the approved tagged forwarding list.

D:

Multi-tenancy requires explicit mapping between shared physical switching resources and FortiGate virtual domains; port sharing alone does not provide isolation. The cause in the stated scenario is different: A physically active switch trunk can still discard frames whose VLAN identifiers are not included in the approved tagged forwarding list.

Question 19

A switch receives tagged VLAN 120 traffic on an uplink where only VLAN 130 is admitted, and the host cannot reach its gateway. Which observation would most directly confirm a successful correction?

  1. Confirm Internet access for guests and explicit denial of management service addresses from the guest segment.
  2. Check the managed port configuration and confirm the client is learned in the intended VLAN after reconnecting.
  3. Ping the applicable gateways and test authorized inter-subnet sessions while confirming disallowed flows are denied.
  4. Use per-port VLAN configuration and a controlled tagged test to show that allowed frames forward while an unapproved tag stays blocked.

Explanation

Correct Answer

D:

Use per-port VLAN configuration and a controlled tagged test to show that allowed frames forward while an unapproved tag stays blocked. This checks the outcome of the selected action: Inspect the allowed VLAN configuration for the ingress and egress ports and admit only the intended VLAN tag. The relevant network behavior is: A physically active switch trunk can still discard frames whose VLAN identifiers are not included in the approved tagged forwarding list.

Other Answers

A:

Confirm Internet access for guests and explicit denial of management service addresses from the guest segment. That test would be valuable for a different deployment: A guest VLAN can reach an internal management VLAN because its switch and firewall security boundaries were not independently defined. For the current scenario it does not validate the targeted fix; the necessary evidence is: Use per-port VLAN configuration and a controlled tagged test to show that allowed frames forward while an unapproved tag stays blocked.

B:

Check the managed port configuration and confirm the client is learned in the intended VLAN after reconnecting. This could confirm success where a newly authorized FortiSwitch shows the correct VLAN object on FortiGate, but the edge port still puts connected devices into the old subnet. The requested condition should instead be verified by: Use per-port VLAN configuration and a controlled tagged test to show that allowed frames forward while an unapproved tag stays blocked.

C:

Ping the applicable gateways and test authorized inter-subnet sessions while confirming disallowed flows are denied. That test would be valuable for a different deployment: Clients in two VLANs can reach their own gateways but inter-VLAN applications are blocked despite switch port links being healthy. For the current scenario it does not validate the targeted fix; the necessary evidence is: Use per-port VLAN configuration and a controlled tagged test to show that allowed frames forward while an unapproved tag stays blocked.

Question 20

A switch receives tagged VLAN 120 traffic on an uplink where only VLAN 130 is admitted, and the host cannot reach its gateway. Which standard operating rule most directly addresses future recurrence?

  1. Require rule-shadow checks and least-privilege regression tests for every ACL change.
  2. Include positive and negative VLAN-tag tests in trunk change acceptance.
  3. Maintain matching trunk-allowed VLAN inventories and test each new VLAN end to end before handover.
  4. Enforce least-privilege administrator profiles and periodic tenant entitlement reviews.

Explanation

Correct Answer

B:

Include positive and negative VLAN-tag tests in trunk change acceptance. This guards against recurrence because A physically active switch trunk can still discard frames whose VLAN identifiers are not included in the approved tagged forwarding list.

Other Answers

A:

Require rule-shadow checks and least-privilege regression tests for every ACL change. That guardrail is most relevant when a FortiSwitch port ACL has a broad permit above a narrow intended deny, allowing an unapproved subnet to reach a sensitive service. It would not reliably prevent the stated problem. The direct preventive control is: Include positive and negative VLAN-tag tests in trunk change acceptance.

C:

Maintain matching trunk-allowed VLAN inventories and test each new VLAN end to end before handover. That guardrail is most relevant when an uplink between two FortiSwitch units carries the default VLAN but drops tagged voice VLAN 230 at the second switch. It would not reliably prevent the stated problem. The direct preventive control is: Include positive and negative VLAN-tag tests in trunk change acceptance.

D:

Enforce least-privilege administrator profiles and periodic tenant entitlement reviews. That preventive measure addresses another exposure: An outsourced operator needs to manage only one customer's FortiSwitch ports but is granted global FortiGate administrative privileges. This scenario requires the following control to reduce recurrence: Include positive and negative VLAN-tag tests in trunk change acceptance.

Fortinet NSE 5 - FortiSwitch 7.6 Administrator (NSE5_FSW_AD-7.6) Practice Tests