McAfee Secured

CompTIA SK0-005 Bundle

Exam Code: SK0-005

Exam Name CompTIA Server+ Certification Exam

Certification Provider: CompTIA

Corresponding Certification: CompTIA Server+

CompTIA SK0-005 Bundle $44.99

Pass CompTIA SK0-005 with Real Questions From Testking

Download Web's Best SK0-005 Exam Preparation Materials Today

  • Questions & Answers

    SK0-005 Questions & Answers

    617 Questions & Answers

    Questions & Answers Testing Engine software allows you to practice questions and answers in real SK0-005 exam environment.

  • SK0-005 Video Course

    SK0-005 Video Course

    139 Video Lectures

    SK0-005 Video Course is developed by CompTIA Professionals to help you pass SK0-005 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA Server+ Certification Exam exam.
  • Study Guide

    SK0-005 Study Guide

    533 PDF Pages

    Study Guide will give you a practical experience regarding the subject and provide an academic background. SK0-005 Study Guide is available in PDF format.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    617 Questions

    $124.99
  • SK0-005 Video Course

    Video Course

    139 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    533 PDF Pages

    $29.99

CompTIA SK0-005 Practice Test 9

Question 80

A server has intermittent NIC resets after firmware maintenance and its adapter driver is older than the newly approved firmware. After the change — Compare the installed driver and firmware pairing with the manufacturer's supported matrix. — which result would best demonstrate that it worked?

  1. The supported pair passes network soak tests without link resets.
  2. The replacement DIMM passes memory diagnostics and corrected-error counts stop increasing.
  3. The link negotiates the expected rate and sustained transfer shows no growing error count.
  4. The weekend batch completes and the deferred restart occurs after checkpoint completion.

Explanation

Correct Answer

A:

The supported pair passes network soak tests without link resets. The result demonstrates the repair under real operating conditions. Compare the installed driver and firmware pairing with the manufacturer's supported matrix. It limits the chance that a mismatched adapter stack can interrupt business connections unpredictably.

Incorrect Answers

B:

Recurring corrected memory faults can precede uncorrectable failures and require slot-specific diagnosis. This relates to a separate check and does not verify the specified repair. The relevant acceptance evidence is: The supported pair passes network soak tests without link resets.

C:

Physical-link characteristics constrain throughput independently of server CPU and software. This relates to a separate check and does not verify the specified repair. The relevant acceptance evidence is: The supported pair passes network soak tests without link resets.

D:

Maintenance scheduling is part of application availability and must account for active transactions. This relates to a separate check and does not verify the specified repair. The relevant acceptance evidence is: The supported pair passes network soak tests without link resets.

Question 81

A regional archive has excellent door locks but no environmental sensor alarms for rising rack humidity. What is the most appropriate next server administration action?

  1. Disable unnecessary services and close associated ports after testing application dependencies.
  2. Apply a legally approved hold to the identified data and document custodial controls.
  3. Install calibrated humidity and temperature monitoring with documented response thresholds.
  4. Adopt application-consistent replication or recovery checkpoints for the protected workload.

Explanation

Correct Answer

C:

Install calibrated humidity and temperature monitoring with documented response thresholds. The change addresses the dependency rather than an adjacent symptom. Physical security includes environmental availability threats as well as unauthorized access. Verification: A safe simulated sensor excursion generates an actionable facilities notification.

Incorrect Answers

A:

Reducing exposed attack surface limits paths an attacker can reach. That is relevant to a different intervention. For the stated situation, the required action is: Install calibrated humidity and temperature monitoring with documented response thresholds. The governing reason is: Physical security includes environmental availability threats as well as unauthorized access.

B:

Legal preservation obligations can override routine retention expiration for scoped records. That is relevant to a different intervention. For the stated situation, the required action is: Install calibrated humidity and temperature monitoring with documented response thresholds. The governing reason is: Physical security includes environmental availability threats as well as unauthorized access.

D:

Crash-consistent file copies may not preserve the application transaction boundary. That is relevant to a different intervention. For the stated situation, the required action is: Install calibrated humidity and temperature monitoring with documented response thresholds. The governing reason is: Physical security includes environmental availability threats as well as unauthorized access.

Question 82

An operations engineer's first theory for slow storage is unsupported by measurements but the team continues changing storage settings. After the change — Reject the unsupported hypothesis and form a new theory using current performance evidence. — which result would best demonstrate that it worked?

  1. The fault returns or disappears consistently with the single identified change.
  2. An IPv6 client connects and IPv4 service remains functional under expected policy.
  3. The repaired volume mounts and recovered files pass content validation.
  4. A new diagnostic test identifies the actual shared contention and repair returns latency to baseline.

Explanation

Correct Answer

D:

A new diagnostic test identifies the actual shared contention and repair returns latency to baseline. This is the required observable result. Reject the unsupported hypothesis and form a new theory using current performance evidence. The original risk was: Continuing an invalid theory wastes downtime and can damage working configurations.

Incorrect Answers

A:

Controlled diagnostic changes preserve causal evidence and make rollback reliable. This relates to a separate check and does not verify the specified repair. The relevant acceptance evidence is: A new diagnostic test identifies the actual shared contention and repair returns latency to baseline.

B:

Dual-stack operation needs complete route and filtering paths for the chosen address family. This relates to a separate check and does not verify the specified repair. The relevant acceptance evidence is: A new diagnostic test identifies the actual shared contention and repair returns latency to baseline.

C:

Filesystem metadata faults require evidence-based recovery rather than automatic reinitialization. This relates to a separate check and does not verify the specified repair. The relevant acceptance evidence is: A new diagnostic test identifies the actual shared contention and repair returns latency to baseline.

Question 83

An analytics company migrates a large database host to a new GPT disk but boots the installer using incompatible legacy firmware mode. The team proposes: Align the operating-system boot mode, partition table and firmware support for the target machine. Which technical principle best explains the decision?

  1. Data migration must preserve both file content and its security metadata.
  2. Load balancing provides availability only when it excludes instances unable to serve transactions.
  3. Scripting at scale magnifies both reliable changes and operator mistakes.
  4. Partition table and firmware boot mode must be compatible for a machine to find its bootloader.

Explanation

Correct Answer

D:

Partition table and firmware boot mode must be compatible for a machine to find its bootloader. The principle identifies the control actually at risk. Align the operating-system boot mode, partition table and firmware support for the target machine. It should produce: The server cold-boots from the intended GPT system disk with the correct UEFI entry.

Incorrect Answers

A:

Data migration must preserve both file content and its security metadata. This does not establish the proposed intervention. The governing principle here is: Partition table and firmware boot mode must be compatible for a machine to find its bootloader. Apply it by: Align the operating-system boot mode, partition table and firmware support for the target machine.

B:

Load balancing provides availability only when it excludes instances unable to serve transactions. This does not establish the proposed intervention. The governing principle here is: Partition table and firmware boot mode must be compatible for a machine to find its bootloader. Apply it by: Align the operating-system boot mode, partition table and firmware support for the target machine.

C:

Scripting at scale magnifies both reliable changes and operator mistakes. This does not establish the proposed intervention. The governing principle here is: Partition table and firmware boot mode must be compatible for a machine to find its bootloader. Apply it by: Align the operating-system boot mode, partition table and firmware support for the target machine.

Question 84

A remote user cannot open a network share after a group policy refresh, but authentication remains successful. What is the most direct risk if this problem remains unresolved?

  1. Disabling SELinux to mask a label issue weakens the entire host boundary.
  2. Formatting the volume can destroy otherwise recoverable research data.
  3. Misdiagnosing an ACL issue can cause dangerous blanket access changes.
  4. Replacing unrelated hardware delays recovery while the actual disk worsens.

Explanation

Correct Answer

C:

Misdiagnosing an ACL issue can cause dangerous blanket access changes. The stated weakness directly creates that exposure. Authentication only establishes identity; separate authorization controls decide resource access. Reduce it by: Inspect effective share and NTFS permissions plus the updated group policy scope.

Incorrect Answers

A:

Mandatory access controls can deny actions that ordinary file permissions permit. That does not describe the principal exposure from the stated failure. The direct avoidable risk is: Misdiagnosing an ACL issue can cause dangerous blanket access changes.

B:

Filesystem metadata faults require evidence-based recovery rather than automatic reinitialization. That does not describe the principal exposure from the stated failure. The direct avoidable risk is: Misdiagnosing an ACL issue can cause dangerous blanket access changes.

D:

Failure indicators identify the subsystem to investigate and should guide replacement decisions. That does not describe the principal exposure from the stated failure. The direct avoidable risk is: Misdiagnosing an ACL issue can cause dangerous blanket access changes.

Question 85

A scientific lab creates a filesystem on the wrong logical volume after confusing SAN LUN identifiers. What is the most appropriate next server administration action?

  1. Replace the shelf assembly with a chassis-compatible four-post rail kit and verify the supported mounting depth.
  2. Stage a vendor-approved firmware update on a pilot node with rollback and service compatibility checks.
  3. Document chassis-wide shared components and add independent chassis capacity for critical service redundancy.
  4. Map the device WWIDs to documented LUN ownership before any destructive formatting or partitioning.

Explanation

Correct Answer

D:

Map the device WWIDs to documented LUN ownership before any destructive formatting or partitioning. This targets the stated fault because block device identity must be verified independently of transient operating-system device names. After repair, the intended LUN is formatted and all unrelated storage WWIDs remain unchanged.

Incorrect Answers

A:

Server mechanical support must match the chassis weight and rack depth rather than merely fit the front screws. That is relevant to a different intervention. For the stated situation, the required action is: Map the device WWIDs to documented LUN ownership before any destructive formatting or partitioning. The governing reason is: Block device identity must be verified independently of transient operating-system device names.

B:

Firmware maintenance can change boot and device behavior and should use controlled compatibility testing. That is relevant to a different intervention. For the stated situation, the required action is: Map the device WWIDs to documented LUN ownership before any destructive formatting or partitioning. The governing reason is: Block device identity must be verified independently of transient operating-system device names.

C:

Blade density increases reliance on shared enclosure resources that must be included in fault-tolerance design. That is relevant to a different intervention. For the stated situation, the required action is: Map the device WWIDs to documented LUN ownership before any destructive formatting or partitioning. The governing reason is: Block device identity must be verified independently of transient operating-system device names.

Question 86

A database server reports corrected ECC memory errors that rapidly increase before sporadic crashes. After the change — Correlate ECC counters to a specific DIMM and replace the verified failing module through approved service. — which result would best demonstrate that it worked?

  1. POST succeeds and diagnostics detect the correct adapter under stress.
  2. An unauthorized test source is blocked while the approved management subnet remains allowed.
  3. A test restoration retrieves the selected recovery point and verifies sample file hashes.
  4. The replacement DIMM passes memory diagnostics and corrected-error counts stop increasing.

Explanation

Correct Answer

D:

The replacement DIMM passes memory diagnostics and corrected-error counts stop increasing. The result demonstrates the repair under real operating conditions. Correlate ECC counters to a specific DIMM and replace the verified failing module through approved service. It limits the chance that the defective memory can progress to uncorrectable crashes and data corruption.

Incorrect Answers

A:

Poor electrical contact can prevent device enumeration even when parts are compatible. This relates to a separate check and does not verify the specified repair. The relevant acceptance evidence is: The replacement DIMM passes memory diagnostics and corrected-error counts stop increasing.

B:

A configured deny rule may be bypassed when a broader higher-precedence allow matches first. This relates to a separate check and does not verify the specified repair. The relevant acceptance evidence is: The replacement DIMM passes memory diagnostics and corrected-error counts stop increasing.

C:

Restore procedures depend on locating the correct base and dependent backup media. This relates to a separate check and does not verify the specified repair. The relevant acceptance evidence is: The replacement DIMM passes memory diagnostics and corrected-error counts stop increasing.

Question 87

A data center replaces a network adapter but leaves its firmware incompatible with the installed system ROM. What is the most direct risk if this problem remains unresolved?

  1. Repeated restarts can conceal a heat fault and damage components.
  2. An incompatible adapter can destabilize the system under I/O load.
  3. Underestimated storage consumption can stop backups without warning.
  4. A firmware mismatch can cause intermittent network loss after a repair.

Explanation

Correct Answer

D:

A firmware mismatch can cause intermittent network loss after a repair. The risk is connected to the particular hardware or process gap. Use the manufacturer-supported adapter firmware and system firmware combination after checking HCL guidance. Confirm through: Boot logs enumerate the adapter reliably and sustained network tests remain error-free.

Incorrect Answers

A:

Hardware faults should be diagnosed from independent management telemetry before repeated recovery attempts. That does not describe the principal exposure from the stated failure. The direct avoidable risk is: A firmware mismatch can cause intermittent network loss after a repair.

B:

A physical expansion-slot fit does not by itself establish platform or firmware compatibility. That does not describe the principal exposure from the stated failure. The direct avoidable risk is: A firmware mismatch can cause intermittent network loss after a repair.

C:

Redundancy reduces available capacity and must be reflected in storage provisioning. That does not describe the principal exposure from the stated failure. The direct avoidable risk is: A firmware mismatch can cause intermittent network loss after a repair.

Question 88

A service desk group receives Domain Admin privileges to reset ordinary user passwords. What is the most direct risk if this problem remains unresolved?

  1. Former contractors may retain access to production servers.
  2. Excessive helpdesk rights can turn one compromised account into domain takeover.
  3. A rehearsal can accidentally redirect live users to test servers.
  4. A missing incremental link can render later backups unusable.

Explanation

Correct Answer

B:

Excessive helpdesk rights can turn one compromised account into domain takeover. Leaving the defect uncorrected makes this outcome credible. Role-based delegation should give operators only the permissions required for their task. Remedy: Delegate the specific reset right to a restricted scope rather than granting broad domain control.

Incorrect Answers

A:

Identity lifecycle management must align privileges with a continuing verified business need. That does not describe the principal exposure from the stated failure. The direct avoidable risk is: Excessive helpdesk rights can turn one compromised account into domain takeover.

C:

Recovery exercises must not introduce duplicate identities or conflicting routes into live services. That does not describe the principal exposure from the stated failure. The direct avoidable risk is: Excessive helpdesk rights can turn one compromised account into domain takeover.

D:

Backup success logs do not prove all dependent media are present and usable for recovery. That does not describe the principal exposure from the stated failure. The direct avoidable risk is: Excessive helpdesk rights can turn one compromised account into domain takeover.

Question 89

A manufacturing administrator signs into domain controllers with only a reusable password despite an MFA requirement. What is the most appropriate next server administration action?

  1. Require approved multifactor authentication for privileged administrative access.
  2. Inventory media and perform documented approved sanitization before asset transfer.
  3. Keep separate recoverable backup copies outside the primary storage failure domain.
  4. Add authorized rack-level access controls and log verified entry into sensitive cages.

Explanation

Correct Answer

A:

Require approved multifactor authentication for privileged administrative access. The stated step is necessary because a single compromised factor should not grant high-impact server management access. Success means: Admin login succeeds only with the required second factor and failed challenges are logged.

Incorrect Answers

B:

Decommissioning must remove sensitive data before physical custody changes. That is relevant to a different intervention. For the stated situation, the required action is: Require approved multifactor authentication for privileged administrative access. The governing reason is: A single compromised factor should not grant high-impact server management access.

C:

Snapshots on the same storage system do not protect against loss of that whole system. That is relevant to a different intervention. For the stated situation, the required action is: Require approved multifactor authentication for privileged administrative access. The governing reason is: A single compromised factor should not grant high-impact server management access.

D:

Perimeter admission does not establish authorization for every individual server enclosure. That is relevant to a different intervention. For the stated situation, the required action is: Require approved multifactor authentication for privileged administrative access. The governing reason is: A single compromised factor should not grant high-impact server management access.

Question 90

A research server cannot mount an ext4 volume after an abrupt power loss and the operator considers immediate reformatting. What is the most direct risk if this problem remains unresolved?

  1. An incorrect boot path can create repeat outages after maintenance windows.
  2. Formatting the volume can destroy otherwise recoverable research data.
  3. Disabling SELinux to mask a label issue weakens the entire host boundary.
  4. A recurring fault can resurface without warning after the incident closes.

Explanation

Correct Answer

B:

Formatting the volume can destroy otherwise recoverable research data. The stated weakness directly creates that exposure. Filesystem metadata faults require evidence-based recovery rather than automatic reinitialization. Reduce it by: Preserve the disk image where feasible and run appropriate non-destructive filesystem diagnostics before repair.

Incorrect Answers

A:

A boot error can originate from firmware selection even when storage data remains intact. That does not describe the principal exposure from the stated failure. The direct avoidable risk is: Formatting the volume can destroy otherwise recoverable research data.

C:

Mandatory access controls can deny actions that ordinary file permissions permit. That does not describe the principal exposure from the stated failure. The direct avoidable risk is: Formatting the volume can destroy otherwise recoverable research data.

D:

Temporary symptom relief does not eliminate the defect that generated the symptom. That does not describe the principal exposure from the stated failure. The direct avoidable risk is: Formatting the volume can destroy otherwise recoverable research data.