McAfee Secured

CompTIA SK0-005 Bundle

Exam Code: SK0-005

Exam Name CompTIA Server+ Certification Exam

Certification Provider: CompTIA

Corresponding Certification: CompTIA Server+

CompTIA SK0-005 Bundle $44.99

Pass CompTIA SK0-005 with Real Questions From Testking

Download Web's Best SK0-005 Exam Preparation Materials Today

  • Questions & Answers

    SK0-005 Questions & Answers

    617 Questions & Answers

    Questions & Answers Testing Engine software allows you to practice questions and answers in real SK0-005 exam environment.

  • SK0-005 Video Course

    SK0-005 Video Course

    139 Video Lectures

    SK0-005 Video Course is developed by CompTIA Professionals to help you pass SK0-005 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA Server+ Certification Exam exam.
  • Study Guide

    SK0-005 Study Guide

    533 PDF Pages

    Study Guide will give you a practical experience regarding the subject and provide an academic background. SK0-005 Study Guide is available in PDF format.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    617 Questions

    $124.99
  • SK0-005 Video Course

    Video Course

    139 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    533 PDF Pages

    $29.99

CompTIA SK0-005 Practice Test 15

Question 140

A patient-record platform claims high availability with two application nodes but both attach to one unprotected network switch. After the change — Add an independent, tested network path for each node and remove the switch as a common failure point. — which result would best demonstrate that it worked?

  1. A controlled switch outage leaves the application reachable through alternate connectivity.
  2. A staged failback shows identical committed transactions and stable user sessions.
  3. An independent technician locates the server and verifies its assigned network from approved records.
  4. The guest's latency normalizes and host swap activity falls under representative load.

Explanation

Correct Answer

A:

A controlled switch outage leaves the application reachable through alternate connectivity. The result demonstrates the repair under real operating conditions. Add an independent, tested network path for each node and remove the switch as a common failure point. It limits the chance that one network switch failure could disable both active application nodes.

Incorrect Answers

B:

Returning service to a repaired node can be riskier than remaining on a healthy standby. This relates to a separate check and does not verify the specified repair. The relevant acceptance evidence is: A controlled switch outage leaves the application reachable through alternate connectivity.

C:

Configuration management should reflect installed reality to support incident response. This relates to a separate check and does not verify the specified repair. The relevant acceptance evidence is: A controlled switch outage leaves the application reachable through alternate connectivity.

D:

Virtual resource sharing needs capacity controls to prevent guest contention. This relates to a separate check and does not verify the specified repair. The relevant acceptance evidence is: A controlled switch outage leaves the application reachable through alternate connectivity.

Question 141

A hospital mounts its shared NFS export over an untrusted network without restricting allowed client hosts. What is the most appropriate next server administration action?

  1. Review rack load limits and install the new units low in the anchored rack using approved lifting procedures.
  2. Confirm the controller's hot-plug procedure and array status before removing any drive.
  3. Identify the failed supply through supported management indicators and replace only the designated unit.
  4. Constrain NFS export access to approved clients and protect the transport according to the trust boundary.

Explanation

Correct Answer

D:

Constrain NFS export access to approved clients and protect the transport according to the trust boundary. The change addresses the dependency rather than an adjacent symptom. File-based shared storage requires explicit authorization as well as network connectivity. Verification: An approved host mounts the export while a test host outside the allowlist is rejected.

Incorrect Answers

A:

Heavy rack equipment should be placed to preserve stability and meet floor and enclosure load limits. That is relevant to a different intervention. For the stated situation, the required action is: Constrain NFS export access to approved clients and protect the transport according to the trust boundary. The governing reason is: File-based shared storage requires explicit authorization as well as network connectivity.

B:

Hot-plug capability must be verified for the specific hardware and current array state. That is relevant to a different intervention. For the stated situation, the required action is: Constrain NFS export access to approved clients and protect the transport according to the trust boundary. The governing reason is: File-based shared storage requires explicit authorization as well as network connectivity.

C:

Hot-swap work must preserve the healthy power path and follow the vendor service procedure. That is relevant to a different intervention. For the stated situation, the required action is: Constrain NFS export access to approved clients and protect the transport according to the trust boundary. The governing reason is: File-based shared storage requires explicit authorization as well as network connectivity.

Question 142

A regional archive has excellent door locks but no environmental sensor alarms for rising rack humidity. After the change — Install calibrated humidity and temperature monitoring with documented response thresholds. — which result would best demonstrate that it worked?

  1. A facilities inspection verifies the authorized system and documented emergency procedures.
  2. A safe simulated sensor excursion generates an actionable facilities notification.
  3. An unauthorized console user cannot change boot order or disable approved security settings.
  4. Database workload latency remains acceptable and approved malware tests are detected outside exclusions.

Explanation

Correct Answer

B:

A safe simulated sensor excursion generates an actionable facilities notification. This is the required observable result. Install calibrated humidity and temperature monitoring with documented response thresholds. The original risk was: Humidity can corrode electronics before technicians discover the condition.

Incorrect Answers

A:

Fire protection must meet life-safety requirements while accounting for equipment exposure. This relates to a separate check and does not verify the specified repair. The relevant acceptance evidence is: A safe simulated sensor excursion generates an actionable facilities notification.

C:

Boot-chain controls must cover firmware settings as well as the operating system. This relates to a separate check and does not verify the specified repair. The relevant acceptance evidence is: A safe simulated sensor excursion generates an actionable facilities notification.

D:

Host protection must preserve security coverage without disrupting application-critical I/O patterns. This relates to a separate check and does not verify the specified repair. The relevant acceptance evidence is: A safe simulated sensor excursion generates an actionable facilities notification.

Question 143

A web cluster node suddenly powers off during peak load and its out-of-band log shows a failed PSU. What is the most appropriate next server administration action?

  1. Verify the affected power path and replace the failed supply with a supported unit.
  2. Identify the incompatible dependency and stage a supported application and runtime combination.
  3. Inspect effective ACLs and inherited permissions before broadening directory access.
  4. Verify optical or copper media compatibility, link negotiation and error counters on both ends.

Explanation

Correct Answer

A:

Verify the affected power path and replace the failed supply with a supported unit. The stated step is necessary because unexpected shutdowns may originate from the hardware power subsystem rather than the operating system. Success means: Power event alarms clear and the node sustains peak load with redundant feeds.

Incorrect Answers

B:

Version compatibility must be validated through the full software dependency stack. That is relevant to a different intervention. For the stated situation, the required action is: Verify the affected power path and replace the failed supply with a supported unit. The governing reason is: Unexpected shutdowns may originate from the hardware power subsystem rather than the operating system.

C:

File access follows actual effective permissions, not only a user's group label. That is relevant to a different intervention. For the stated situation, the required action is: Verify the affected power path and replace the failed supply with a supported unit. The governing reason is: Unexpected shutdowns may originate from the hardware power subsystem rather than the operating system.

D:

Physical-link characteristics constrain throughput independently of server CPU and software. That is relevant to a different intervention. For the stated situation, the required action is: Verify the affected power path and replace the failed supply with a supported unit. The governing reason is: Unexpected shutdowns may originate from the hardware power subsystem rather than the operating system.

Question 144

An operator sees frequent medium errors on one drive but blames the NFS client because the user reports slow files. After the change — Correlate controller media counters and array health before changing client mounts. — which result would best demonstrate that it worked?

  1. The OS reports the new filesystem size and performs a write test without errors.
  2. The failing drive is replaced and NFS read latency improves without client configuration changes.
  3. Disk SMART/controller warnings identify the suspect device and CPU diagnostics remain normal.
  4. A rollback pilot correlates the firmware version with the observed crash signature.

Explanation

Correct Answer

B:

The failing drive is replaced and NFS read latency improves without client configuration changes. This tests the affected component rather than an unrelated service. Storage symptoms visible through file sharing can originate on the underlying block media. Without the change, ignoring media faults can progress to data loss during rebuild.

Incorrect Answers

A:

Storage capacity is exposed through several layers that must each recognize the change. This relates to a separate check and does not verify the specified repair. The relevant acceptance evidence is: The failing drive is replaced and NFS read latency improves without client configuration changes.

C:

Failure indicators identify the subsystem to investigate and should guide replacement decisions. This relates to a separate check and does not verify the specified repair. The relevant acceptance evidence is: The failing drive is replaced and NFS read latency improves without client configuration changes.

D:

Recent environmental changes are high-value evidence when forming a probable-cause theory. This relates to a separate check and does not verify the specified repair. The relevant acceptance evidence is: The failing drive is replaced and NFS read latency improves without client configuration changes.

Question 145

A data center schedules replacement of a failing memory module but does not preserve the slot and part compatibility records. What is the most appropriate next server administration action?

  1. Map corrected ECC errors to the documented slot and fit an approved module after safe isolation.
  2. Map the device WWIDs to documented LUN ownership before any destructive formatting or partitioning.
  3. Replace the shelf assembly with a chassis-compatible four-post rail kit and verify the supported mounting depth.
  4. Feed the separate supply inputs from approved independent PDUs and upstream circuits.

Explanation

Correct Answer

A:

Map corrected ECC errors to the documented slot and fit an approved module after safe isolation. This targets the stated fault because hardware maintenance is most reliable when diagnostic evidence identifies the replaceable unit and compatible part. After repair, the DIMM inventory matches the recorded slot and diagnostic tests report no recurring ECC faults.

Incorrect Answers

B:

Block device identity must be verified independently of transient operating-system device names. That is relevant to a different intervention. For the stated situation, the required action is: Map corrected ECC errors to the documented slot and fit an approved module after safe isolation. The governing reason is: Hardware maintenance is most reliable when diagnostic evidence identifies the replaceable unit and compatible part.

C:

Server mechanical support must match the chassis weight and rack depth rather than merely fit the front screws. That is relevant to a different intervention. For the stated situation, the required action is: Map corrected ECC errors to the documented slot and fit an approved module after safe isolation. The governing reason is: Hardware maintenance is most reliable when diagnostic evidence identifies the replaceable unit and compatible part.

D:

Two power supplies do not protect against a common downstream breaker or PDU fault. That is relevant to a different intervention. For the stated situation, the required action is: Map corrected ECC errors to the documented slot and fit an approved module after safe isolation. The governing reason is: Hardware maintenance is most reliable when diagnostic evidence identifies the replaceable unit and compatible part.

Question 146

A laboratory allocates all vCPUs to one VM, leaving the host with no resources for management services. What is the most appropriate next server administration action?

  1. Rebalance virtual CPU reservations and retain required hypervisor management capacity.
  2. Choose a supported clustering or storage architecture that respects the application's write model.
  3. Add conditional checks and stop the run when the required dependencies are unhealthy.
  4. Update protected diagrams and recovery runbooks whenever approved topology changes occur.

Explanation

Correct Answer

A:

Rebalance virtual CPU reservations and retain required hypervisor management capacity. The host must preserve resources for scheduling and management even when guests need high throughput. Check the outcome directly: Host control-plane latency stays within limits while the guest meets its compute target. The unresolved risk would be: Management starvation can make an otherwise healthy host unmanageable.

Incorrect Answers

B:

Parallel service nodes cannot safely share mutable state without an appropriate consistency mechanism. That is relevant to a different intervention. For the stated situation, the required action is: Rebalance virtual CPU reservations and retain required hypervisor management capacity. The governing reason is: The host must preserve resources for scheduling and management even when guests need high throughput.

C:

Conditional scripting prevents hazardous operations when preconditions are not satisfied. That is relevant to a different intervention. For the stated situation, the required action is: Rebalance virtual CPU reservations and retain required hypervisor management capacity. The governing reason is: The host must preserve resources for scheduling and management even when guests need high throughput.

D:

Recovery documents must describe the current environment rather than a historical configuration. That is relevant to a different intervention. For the stated situation, the required action is: Rebalance virtual CPU reservations and retain required hypervisor management capacity. The governing reason is: The host must preserve resources for scheduling and management even when guests need high throughput.

Question 147

A records agency mirrors files to a secondary system while an application writes are not synchronized into consistent restore points. After the change — Adopt application-consistent replication or recovery checkpoints for the protected workload. — which result would best demonstrate that it worked?

  1. A simulated restoration opens the expected application with valid recovered data.
  2. The pilot passes vulnerability checks and the service survives a controlled rollback test.
  3. A recovery exercise replays transactions and opens the dataset without database repair.
  4. A selected offsite tape is retrieved and restored into an isolated test environment.

Explanation

Correct Answer

C:

A recovery exercise replays transactions and opens the dataset without database repair. Crash-consistent file copies may not preserve the application transaction boundary. The test establishes that the fix addresses the specific failure.

Incorrect Answers

A:

Tabletop planning tests decisions but not whether systems actually start and connect. This relates to a separate check and does not verify the specified repair. The relevant acceptance evidence is: A recovery exercise replays transactions and opens the dataset without database repair.

B:

Secure patching must balance exposure reduction against service availability and rollback readiness. This relates to a separate check and does not verify the specified repair. The relevant acceptance evidence is: A recovery exercise replays transactions and opens the dataset without database repair.

D:

Offsite backup storage mitigates site-wide fire, theft and flood failure domains. This relates to a separate check and does not verify the specified repair. The relevant acceptance evidence is: A recovery exercise replays transactions and opens the dataset without database repair.

Question 148

A multinational business begins a volume license true-up without reconciling systems recently decommissioned. After the change — Reconcile active deployments, retired systems and license consumption before submitting true-up counts. — which result would best demonstrate that it worked?

  1. Inventory of covered cores matches the valid license grant after remediation.
  2. An approved administrator reaches SSH while Telnet is closed to the management network.
  3. The true-up ledger matches audited running instances and documented retired assets.
  4. The server cold-boots from the intended GPT system disk with the correct UEFI entry.

Explanation

Correct Answer

C:

The true-up ledger matches audited running instances and documented retired assets. This is the required observable result. Reconcile active deployments, retired systems and license consumption before submitting true-up counts. The original risk was: Inflated or missing usage counts can cause excess charges or contractual breaches.

Incorrect Answers

A:

Licensing measurements depend on the agreed unit of entitlement, not generic host count. This relates to a separate check and does not verify the specified repair. The relevant acceptance evidence is: The true-up ledger matches audited running instances and documented retired assets.

B:

Administrative credentials and commands should be protected in transit. This relates to a separate check and does not verify the specified repair. The relevant acceptance evidence is: The true-up ledger matches audited running instances and documented retired assets.

D:

Partition table and firmware boot mode must be compatible for a machine to find its bootloader. This relates to a separate check and does not verify the specified repair. The relevant acceptance evidence is: The true-up ledger matches audited running instances and documented retired assets.

Question 149

A contractor's temporary admin account stays active for months after the engagement ends. After the change — Enforce time-limited access and disable the account at the approved contract boundary. — which result would best demonstrate that it worked?

  1. The effective-access report shows only authorized groups can read the protected share.
  2. A rehearsal starts isolated recovery systems without affecting production name resolution.
  3. The expired account fails a login test while approved permanent operators retain their roles.
  4. A controlled restore recovers an earlier known-good file version from the retained history.

Explanation

Correct Answer

C:

The expired account fails a login test while approved permanent operators retain their roles. The evidence matches the stated repair. Identity lifecycle management must align privileges with a continuing verified business need.

Incorrect Answers

A:

Group inheritance can grant access beyond the permissions explicitly visible on one user account. This relates to a separate check and does not verify the specified repair. The relevant acceptance evidence is: The expired account fails a login test while approved permanent operators retain their roles.

B:

Recovery exercises must not introduce duplicate identities or conflicting routes into live services. This relates to a separate check and does not verify the specified repair. The relevant acceptance evidence is: The expired account fails a login test while approved permanent operators retain their roles.

D:

Backup rotation must account for delayed discovery of corruption and destructive updates. This relates to a separate check and does not verify the specified repair. The relevant acceptance evidence is: The expired account fails a login test while approved permanent operators retain their roles.

Question 150

A virtual host reports thermal throttling after a maintenance technician incorrectly seats a CPU heat sink. The team proposes: Inspect approved thermal assembly and fan telemetry and reseat the sink under vendor procedure. Which technical principle best explains the decision?

  1. Heat transfer depends on correct physical heat-sink contact as well as fan function.
  2. File access follows actual effective permissions, not only a user's group label.
  3. Successful backup writing requires capacity for the complete job and its metadata.
  4. Dual-stack operation needs complete route and filtering paths for the chosen address family.

Explanation

Correct Answer

A:

Heat transfer depends on correct physical heat-sink contact as well as fan function. That mechanism makes the proposed response appropriate. Inspect approved thermal assembly and fan telemetry and reseat the sink under vendor procedure. Evidence: CPU temperature remains inside limits and clock rates recover under a load test.

Incorrect Answers

B:

File access follows actual effective permissions, not only a user's group label. This does not establish the proposed intervention. The governing principle here is: Heat transfer depends on correct physical heat-sink contact as well as fan function. Apply it by: Inspect approved thermal assembly and fan telemetry and reseat the sink under vendor procedure.

C:

Successful backup writing requires capacity for the complete job and its metadata. This does not establish the proposed intervention. The governing principle here is: Heat transfer depends on correct physical heat-sink contact as well as fan function. Apply it by: Inspect approved thermal assembly and fan telemetry and reseat the sink under vendor procedure.

D:

Dual-stack operation needs complete route and filtering paths for the chosen address family. This does not establish the proposed intervention. The governing principle here is: Heat transfer depends on correct physical heat-sink contact as well as fan function. Apply it by: Inspect approved thermal assembly and fan telemetry and reseat the sink under vendor procedure.