McAfee Secured

Exam Code: 220-1202

Exam Name: CompTIA A+ Certification Exam: Core 2

Certification Provider: CompTIA

Corresponding Certification: CompTIA A+

100% CompTIA 220-1202 Guaranteed Success With Testking Training Materials

Get Real 220-1202 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

417 Questions & Answers with Testing Engine

"CompTIA A+ Certification Exam: Core 2 Exam", also known as 220-1202 exam, is a CompTIA certification exam.

Pass your tests with the always up-to-date 220-1202 Exam Engine. Your 220-1202 training materials keep you at the head of the pack!

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Was: $137.49
Now: $124.99

CompTIA 220-1202 Practice Test 74

Question 730

An IT storeroom has unusually high humidity and metal components develop condensation after overnight cooling. Which environmental or power-management action is appropriate?

  1. Store electronics in uncontrolled extreme humidity and rely on sealed cardboard cartons alone.
  2. Turn off environmental monitoring because hardware appears to be working.
  3. Place room humidifiers directly above energized rack equipment.
  4. Monitor and control environmental humidity and allow equipment to acclimate before energizing.

Explanation

Correct Answer

D:

Moisture and condensation can corrode conductors and cause short circuits on energized devices. Condensation can damage circuitry even when the measured room temperature seems acceptable.

Incorrect Answers

A:

Excess moisture can lead to condensation and corrosion, while very dry air can raise static risk.

B:

Visible normal operation does not measure harmful humidity trends.

C:

Direct moisture near live hardware risks water damage and electrical faults.

Question 731

A server cabinet has all fans running but exhaust air is drawn back into the front intake because of poor rack placement. Which environmental or power-management action is appropriate?

  1. Point the rack fans so heated exhaust immediately recirculates into adjacent air intakes.
  2. Stack unused equipment across the rack ventilation paths.
  3. Turn off temperature alerts to avoid distracting support staff.
  4. Reconfigure airflow paths and rack layout, verify inlet temperatures and maintain clear separation of hot exhaust.

Explanation

Correct Answer

D:

Recirculation defeats cooling despite functional fans and can raise component inlet temperature. Servers may throttle or shut down when intake air exceeds safe limits.

Incorrect Answers

A:

Recirculation increases inlet temperatures and undermines the cooling system.

B:

Blocked airflow prevents designed heat removal.

C:

Warnings cannot be replaced by reduced visibility into overheating.

Question 732

A repair shop collects undamaged spent phone batteries in a metal tray. Several loose packs have exposed terminals that can touch each other during transport. Which immediate packaging change reduces the specific risk?

  1. Mix the batteries with metal screws so the tray fills evenly.
  2. Stack exposed terminals face-to-face and place a heavy power adapter on top.
  3. Protect each battery’s exposed terminals against contact and place packs in suitable separate nonconductive packaging for approved collection.
  4. Test each pack by shorting its terminals briefly to confirm it is depleted.

Explanation

Correct Answer

C:

Terminal insulation and approved packaging prevent adjacent battery contacts from forming an unintended circuit in transit.

Incorrect Answers

A:

Metal screws can bridge battery contacts and create heat or fire risk.

B:

Direct terminal contact and pressure increase the chance of shorts or physical damage.

D:

Shorting a lithium battery is unsafe even when the pack appears discharged.

Question 733

A network rack has clear front and rear floor space and functioning fans, but internal temperature sensors show hot exhaust recirculating through open gaps between rack-mounted devices. What should facilities and IT change?

  1. Fit approved rack blanking panels and airflow management to separate cold intake from hot exhaust, then verify temperatures under load.
  2. Remove all cabinet doors without checking how the room supplies and returns cooling air.
  3. Increase device CPU load so the equipment fans move more hot air through the rack gaps.
  4. Place a portable heater at the rack intake to reduce condensation regardless of sensor data.

Explanation

Correct Answer

A:

Blanking unused rack spaces limits recirculation of exhaust air into equipment intakes; follow-up readings validate the airflow correction.

Incorrect Answers

B:

Removing doors may disturb the designed airflow pattern and does not specifically seal the identified recirculation gaps.

C:

Increasing heat generation intensifies the thermal problem rather than separating intake and exhaust paths.

D:

Heating the intake is unrelated to the documented elevated rack temperature and can worsen it.

Question 734

A branch server room has no temperature alarms, and staff discover cooling failure only after a weekend outage. Which response directly addresses the documented problem?

  1. Install appropriate monitored temperature alerts and assign on-call response thresholds.
  2. Wait for servers to shut down from heat before checking any HVAC sensors.
  3. Measure room temperature once at installation and assume it remains stable forever.
  4. Disable alert notifications during weekends although the equipment runs continuously.

Explanation

Correct Answer

A:

Continuous monitoring could identify abnormal heat before servers shut down. A silent air-conditioning failure can damage equipment before anyone visits the room.

Incorrect Answers

B:

Monitoring should provide early warning before equipment reaches a failure threshold.

C:

HVAC failures and changing loads require continuous or periodic monitored conditions.

D:

Unattended failures may progress when the response team has no alarm.

Question 735

A UPS rated only for desktop use is connected to a high-draw server and network switch, then shuts off almost immediately during a test. How should the support team proceed?

  1. Calculate actual watts and runtime, select a suitable UPS and test shutdown at expected load.
  2. Choose a UPS solely by its outlet count without calculating load and desired battery runtime.
  3. Assume a small UPS can power servers indefinitely without a controlled shutdown.
  4. Connect noncritical space heaters to the server UPS to use spare sockets.

Explanation

Correct Answer

A:

Load and required runtime exceed the battery system's supported capacity. An undersized UPS gives false confidence and fails before systems can save data.

Incorrect Answers

B:

Outlet count does not guarantee sufficient VA/watts or operating time for the critical equipment.

C:

Battery capacity is finite and should be matched to required bridging or shutdown time.

D:

High-draw loads can exhaust the reserve before servers shut down cleanly.

Question 736

Old monitors are stacked in a hallway marked as an emergency exit route. Which environmental or power-management action is appropriate?

  1. Store retired PCs in the marked emergency exit route until pickup day.
  2. Place decommissioned racks in front of fire extinguishers to discourage unauthorized use.
  3. Move equipment to an approved storage area and arrange compliant electronics recycling.
  4. Use emergency stairwells as overflow equipment storage after hours.

Explanation

Correct Answer

C:

E-waste storage must not obstruct paths needed for safe evacuation. Obstructed exits can delay evacuation and increase injury during an emergency.

Incorrect Answers

A:

Temporary storage still blocks evacuation and violates safe egress.

B:

Blocking emergency equipment can delay response when it is urgently needed.

D:

Exit routes must remain clear whenever the facility is occupied.

Question 737

A department throws empty toner and ink cartridges in mixed office garbage without reviewing return options. Which environmental or power-management action is appropriate?

  1. Dispose of used toner cartridges in ordinary trash without reviewing vendor or local handling rules.
  2. Follow approved return or recycling programs and handle spills as indicated by safety guidance.
  3. Pour leftover liquid ink into a sink so the empty cartridge can enter paper recycling.
  4. Mix toner powder with depleted lithium batteries in one unlabelled waste carton.

Explanation

Correct Answer

B:

Consumable materials and packaging may have manufacturer or local recycling requirements. Improper disposal can increase waste and potentially release toner or chemicals.

Incorrect Answers

A:

Consumables may require specific recycling or waste handling routes.

C:

Uncontrolled disposal can contaminate drains and does not follow manufacturer guidance.

D:

Different waste streams require safe separation and documented collection.

Question 738

A team enables aggressive sleep timers on an always-on workstation that performs scheduled evening backups. Which environmental or power-management action is appropriate?

  1. Schedule computers to sleep during the critical overnight backup window without wake support.
  2. Disable all equipment power management forever even for idle noncritical systems.
  3. Tune power policy for backup windows and confirm energy-saving settings after backup completion.
  4. Unplug the backup appliance each evening as the main energy-saving measure.

Explanation

Correct Answer

C:

Power savings are useful only when the device remains available for its approved operational tasks. A sleeping backup workstation can silently miss recovery points despite lower electricity use.

Incorrect Answers

A:

Aggressive power settings can interrupt required protection jobs.

B:

A policy can save energy while exempting systems that genuinely need continuous operation.

D:

A powered-off backup target cannot receive scheduled night jobs.

Question 739

An office connects multiple power strips end to end to serve more desk equipment. Which environmental or power-management action is appropriate?

  1. Connect another extension strip into the first without checking load or circuit ratings.
  2. Use approved suitably rated distribution and request facilities review of power needs.
  3. Ignore warmed plugs because all equipment still operates normally.
  4. Use a lightweight consumer strip for a high-draw equipment rack without consulting facility electrical limits.

Explanation

Correct Answer

B:

Daisy chaining can exceed ratings and violate electrical safety guidance even when each strip has surge protection. Overloaded connections may overheat and create a fire hazard.

Incorrect Answers

A:

Daisy-chaining increases overheating and fire risk when current draw exceeds safe ratings.

C:

Overheating contacts can be hazardous before a device fails.

D:

An unrated distribution path may overload cables or wall circuits.

Question 740

A branch office disposes of desktops through an informal collector but retains no evidence of responsible downstream processing. Which support action is most appropriate?

  1. Discard retired computer boards and drives in untracked ordinary household waste.
  2. Transfer un-sanitized storage to an unknown recycler without a custody receipt.
  3. Keep only a verbal assurance that devices were recycled and destroy item-level records.
  4. Select an approved recycler, sanitize data separately and retain documented pickup and processing records.

Explanation

Correct Answer

D:

Electronic waste can contain hazardous components and data-bearing media requiring accountable disposition. Untracked disposal can cause environmental harm and leave data-bearing devices unaccounted for.

Incorrect Answers

A:

Electronics and data media may need controlled recycling and sanitization evidence.

B:

Recycling without media controls can disclose sensitive data.

C:

The organization needs auditable asset disposition and appropriate recycling evidence.

CompTIA A+ Certification Exam: Core 2 (220-1202) Practice Tests