Question 170 A weekly full backup is followed by daily incrementals. To recover Friday’s files after a disk loss, what backup sequence must the administrator restore? Restore only the weekly full backup and skip all subsequent incremental backups. Restore the last good full and the valid incremental chain in order, and verify file integrity. Restore only Friday’s incremental backup without restoring the full backup first. Restore the weekly full backup and only the most recent incremental, omitting intervening daily incrementals. Explanation Correct Answer B:Incremental backups preserve changes since the most recent backup, so a full plus each required subsequent incremental is needed. Skipping a needed incremental can leave later changed documents absent from the recovered system. Incorrect Answers A:That would return the system to the full-backup date, losing the changes recorded in later incrementals. C:An incremental contains changes relative to an earlier backup, not a complete independent filesystem baseline. D:The latest daily incremental depends on the preceding incremental chain; omitting steps can leave the restored state incomplete.
Question 171 An office says its backup jobs are successful but has never confirmed that a deleted invoice database can be restored. What is the appropriate backup or recovery step? Trust the green backup-job status without trying to recover any invoice database content. Restore a representative invoice-database backup to an isolated test location, open the recovered database, validate records and document the recovery time. Restore the only production database in place during business hours for an unplanned test. Compare only backup archive file sizes and infer that application records are valid. Explanation Correct Answer B:A successful backup job does not prove that the database is usable. An isolated restore and record-level checks verify recoverability without overwriting current production transactions. Incorrect Answers A:Backup completion does not establish that application data is usable after restore. C:A destructive test risks current transactions; use an isolated recovery destination. D:File size alone cannot verify database consistency or business recovery time.
Question 172 A team takes one full backup each week. Daily full backups are too large for the available storage, but management wants to restore the latest daily recovery point using that weekly full plus just one daily backup. Which compact daily backup type meets this restore-chain requirement? Use incremental daily backups but expect recovery to require only the latest incremental and one full. Use daily differential backups as approved and validate a restore from the full plus the selected differential. Create full backups every day without evaluating storage usage or the stated differential requirement. Delete the weekly full after creating the first differential and rely only on daily files. Explanation Correct Answer B:Differential backups accumulate changes since the last full, unlike incremental backups chaining each daily interval. Confusing differential with incremental sets can lead to incomplete restores and unexpected recovery complexity. Incorrect Answers A:Incremental restores generally depend on the complete sequence since the full. C:Daily full copies may work but ignore the requirement for compact daily backups with a short restore chain. D:A differential depends on its base full backup and cannot replace it.
Question 173 A technician replaces memory modules inside a powered-off desktop on a carpeted bench during very dry weather. How should this work be handled safely? Handle the memory module by its gold contacts to keep fingers off the plastic casing. Work on the carpet because the case is powered off and cannot create static charge. Leave the desktop plugged in and open the chassis so its metal frame remains energized. Disconnect power, use a properly grounded ESD strap and suitable mat, then handle modules by their edges. Explanation Correct Answer D:Sensitive exposed electronic components can be damaged by electrostatic discharge even when mains power is disconnected. Static discharge may cause immediate or latent memory faults that appear only after deployment. Incorrect Answers A:Touching contacts can contaminate them and does not control static discharge into the module. B:Static electricity can exist with the PC off, especially on carpet in a dry environment. C:Leaving power connected exposes the technician to electrical and component damage risk, not a proper grounding plan.
Question 174 A helpdesk worker begins disconnecting an internal power supply while the desktop remains attached to a live outlet. How should this work be handled safely? Unplug only the monitor while the PC power supply remains connected to live mains. Shut down, unplug the device, discharge according to manufacturer guidance, and follow electrical safety policy. Leave the computer on during card or PSU removal so error logs remain visible. Use a metal screwdriver to discharge the mains contacts inside the supply. Explanation Correct Answer B:Internal servicing presents electrical shock and short-circuit risk until equipment is safely powered off and disconnected. Servicing a live internal power circuit can injure the technician or permanently damage components. Incorrect Answers A:The internal power source is still energized and must be handled under the proper safety procedure. C:Internal hardware work should not be done with the host energized. D:Shorting high-energy components is hazardous and not a supported discharge method.
Question 175 Two employees move a large rack-mounted UPS with one person lifting from a twisted posture and no cart. How should this work be handled safely? Have one worker lift the heavy UPS while twisting to avoid a doorway. Drag the UPS by its power cord to reduce the weight being carried. Use the approved lifting plan, team assistance or lift cart, and follow weight and handling guidance. Ignore published unit weight because two people have moved similar equipment before. Explanation Correct Answer C:The mass and awkward position pose a musculoskeletal injury risk requiring suitable handling equipment and assistance. Improper lifting can cause back injury and drop expensive equipment onto people or cables. Incorrect Answers A:An awkward single-person lift increases musculoskeletal injury risk. B:The cord is not a load-bearing handle and can be damaged. D:Rated equipment handling and a suitable lift plan should be based on the actual mass and dimensions.
Question 176 A faulty power strip begins smoking near a workstation, and a worker reaches for a water bucket. How should this work be handled safely? Throw water onto the smoking energized power strip to cool it quickly. Continue using the strip while watching whether the smoke becomes thicker. Open the power strip housing while it is energized to find the hot component. Raise the alarm, move people to safety, disconnect power only if safe, and use a Class C-rated extinguisher only if trained; otherwise evacuate and call responders. Explanation Correct Answer D:Energized electrical equipment requires a suitable Class C-rated extinguisher, not a bucket of water. Protect people and evacuate when safe control of the fire is not possible. Incorrect Answers A:Water can conduct electricity and is not an appropriate uncontrolled response to a live electrical hazard. B:A potentially developing electrical fire calls for immediate alarm and appropriate emergency procedures. C:Exposing live wiring during a smoking event creates an immediate shock and fire risk.
Question 177 A small office file server restarts during brief neighborhood voltage dips even though its power strip claims surge protection. What is the safer handling procedure? Replace the surge strip with a larger surge strip and assume brief outages are now covered. Install an appropriately sized UPS and configure safe shutdown, then test under controlled conditions. Disable clean shutdown for the file server so it never stops during short dips. Plug every office appliance into the proposed backup supply without sizing the protected load. Explanation Correct Answer B:A surge protector does not provide temporary battery-backed power during brownouts and short blackouts. Without battery backup, sudden power loss may corrupt open files and disrupt shared services. Incorrect Answers A:Surge protection does not provide battery runtime through voltage interruptions. C:An abrupt power loss can corrupt data; planned UPS shutdown is part of recovery. D:Overloading a UPS can shorten or eliminate runtime for the critical server.
Question 178 A branch office piles swollen and exhausted lithium laptop batteries in ordinary household trash. What is the safer handling procedure? Place swollen lithium batteries in the ordinary office waste bin with paper recycling. Stack exhausted battery packs next to a heater to dry them before collection. Ship loose battery terminals without protective packaging or vendor instructions. Isolate safely according to vendor guidance and arrange approved battery recycling or hazardous waste collection. Explanation Correct Answer D:Damaged batteries pose fire and environmental risks and require specialized handling under local procedures. Throwing damaged batteries into general waste can cause fires and violate disposal requirements. Incorrect Answers A:Damaged cells can ignite and require approved hazardous battery handling. B:Heat exposure increases failure risk, particularly for swollen cells. C:Short circuits during transport can cause thermal events.
Question 179 A storage closet now holds multiple network switches and NAS units, with blocked vents and rising ambient temperature. What is the safer handling procedure? Stack cartons against the switch exhaust vents to conserve floor space. Install an additional NAS on the same crowded shelf without assessing cooling. Clear air paths, verify safe operating temperature and ventilation, and relocate equipment if necessary. Disable fan alarms to reduce noise while room temperature continues rising. Explanation Correct Answer C:Insufficient airflow and elevated temperature undermine equipment reliability independently of firmware version. Prolonged overheating can shorten component life and produce intermittent device shutdowns. Incorrect Answers A:Blocked ventilation prevents heat removal and worsens the equipment closet temperature. B:More equipment adds heat and airflow restrictions to the already overheating space. D:Silencing warnings does not restore safe operating conditions.
Question 180 A printer technician opens a damaged toner cartridge and powder spills onto a desktop, but staff propose using a household vacuum. What is the safer handling procedure? Vacuum toner with a normal household cleaner without reviewing the manufacturers safety instructions. Consult the applicable safety data guidance, use approved protective equipment and cleanup method, and dispose of waste correctly. Blow the spilled toner across the desk with compressed air. Mix the toner with an arbitrary liquid solvent to make it easier to wipe. Explanation Correct Answer B:Consumable powder handling requires the manufacturer's safety information and suitable cleanup methods. Unapproved vacuuming or dispersal can spread airborne particles and create avoidable exposure. Incorrect Answers A:Fine toner may be dispersed by unsuitable equipment and requires approved cleanup handling. C:Aerosolizing toner increases inhalation and cross-contamination risk. D:Unknown chemical interaction and disposal requirements should be checked first.