McAfee Secured

Exam Code: 220-1201

Exam Name: CompTIA A+ Certification Exam: Core 1

Certification Provider: CompTIA

Corresponding Certification: CompTIA A+

100% CompTIA 220-1201 Guaranteed Success With Testking Training Materials

Get Real 220-1201 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

527 Questions & Answers with Testing Engine

"CompTIA A+ Certification Exam: Core 1 Exam", also known as 220-1201 exam, is a CompTIA certification exam.

Pass your tests with the always up-to-date 220-1201 Exam Engine. Your 220-1201 training materials keep you at the head of the pack!

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Was: $137.49
Now: $124.99

CompTIA 220-1201 Practice Test 74

Question 730

A server's fan makes a grinding sound and CPU temperatures climb even when the case filters are clean. Which failure mode should the technician prioritize?

  1. Failing fan bearing in cooling assembly
  2. Overheating caused by obstructed airflow
  3. Unsupported CPU or firmware initialization failure
  4. Firmware cooling policy causing CPU throttling

Explanation

Correct Answer

A:

The fan rotor wobbles or intermittently stalls and its RPM falls below the specified minimum, consistent with a failing fan bearing in cooling assembly.

Incorrect Answers

B:

Fan speed rises while internal temperature continues increasing and dust blocks the intake, consistent with an overheating caused by obstructed airflow.

C:

The motherboard beep code and CPU support list indicate the processor requires a newer supported BIOS, consistent with an unsupported cpu or firmware initialization failure.

D:

CPU temperature and clock monitoring show thermal limits reached while the fan remains at low RPM, consistent with a firmware cooling policy causing cpu throttling.

Question 731

A help-desk ticket states: A PC powers up but gives a repeating POST beep sequence and no video after a technician installed a new CPU. Which diagnosis is best supported rather than simply possible?

  1. Memory module unseated after transport
  2. Firmware cooling policy causing CPU throttling
  3. Unsupported CPU or firmware initialization failure
  4. Display output routed to wrong graphics port

Explanation

Correct Answer

C:

The motherboard beep code and CPU support list indicate the processor requires a newer supported BIOS, consistent with an unsupported cpu or firmware initialization failure.

Incorrect Answers

A:

The motherboard's documented beep code identifies RAM and inspection finds a DIMM latch not fully closed, consistent with a memory module unseated after transport.

B:

CPU temperature and clock monitoring show thermal limits reached while the fan remains at low RPM, consistent with a firmware cooling policy causing cpu throttling.

D:

The active video signal comes from the discrete card while the monitor is connected to an inactive motherboard output, consistent with a display output routed to wrong graphics port.

Question 732

When comparing several hypotheses, a technician observes: An office machine is unusually slow and the CPU clock stays far below base frequency even at moderate load; the heatsink is secure but its fan profile is set nearly off. Which condition best fits?

  1. Failing fan bearing in cooling assembly
  2. CPU thermal throttling from failed cooling
  3. Unsupported CPU or firmware initialization failure
  4. Firmware cooling policy causing CPU throttling

Explanation

Correct Answer

D:

CPU temperature and clock monitoring show thermal limits reached while the fan remains at low RPM, consistent with a firmware cooling policy causing cpu throttling.

Incorrect Answers

A:

The fan rotor wobbles or intermittently stalls and its RPM falls below the specified minimum, consistent with a failing fan bearing in cooling assembly.

B:

The heatsink fan is stopped and temperature climbs rapidly before the slowdown, consistent with a cpu thermal throttling from failed cooling.

C:

The motherboard beep code and CPU support list indicate the processor requires a newer supported BIOS, consistent with an unsupported cpu or firmware initialization failure.

Question 733

A technician investigates this device problem: A kiosk shows a black screen only after moving to a new monitor, but boot beeps and network remote access show the OS is running. Which diagnosis best explains the observed pattern?

  1. Power supply transient response or headroom shortfall
  2. Power supply capacity inadequate under load
  3. Display output routed to wrong graphics port
  4. Unsupported CPU or firmware initialization failure

Explanation

Correct Answer

C:

The active video signal comes from the discrete card while the monitor is connected to an inactive motherboard output, consistent with a display output routed to wrong graphics port.

Incorrect Answers

A:

Restarts correlate with GPU load transients while thermals remain within safe limits, consistent with a power supply transient response or headroom shortfall.

B:

The shutdown coincides with combined CPU and GPU power demand rather than rising component temperature, consistent with a power supply capacity inadequate under load.

D:

The motherboard beep code and CPU support list indicate the processor requires a newer supported BIOS, consistent with an unsupported cpu or firmware initialization failure.

Question 734

A desktop's hard drive makes repeated clicks at startup and file reads intermittently hang. Which underlying component or configuration issue is most consistent with the evidence?

  1. RAID mirror degraded with one surviving member
  2. Mechanical HDD read-head or actuator failure
  3. Storage IOPS contention under concurrent load
  4. SMART-reported impending disk failure

Explanation

Correct Answer

B:

SMART and vendor diagnostics show increasing media or seek errors alongside audible clicking, consistent with a mechanical hdd read-head or actuator failure.

Incorrect Answers

A:

Array management identifies exactly one failed member and the other mirror disk is healthy, consistent with a raid mirror degraded with one surviving member.

C:

Queue depth and response time rise with backup traffic while disk health reports no failure, consistent with a storage iops contention under concurrent load.

D:

Health attributes exceed vendor-defined thresholds and the firmware marks the disk at risk, consistent with a smart-reported impending disk failure.

Question 735

During a support incident, A storage drive's SMART predictive failure warning appears even though its files are still accessible. What is the most likely technical explanation?

  1. Controller RAID metadata or configuration mismatch
  2. RAID mirror degraded with one surviving member
  3. Mechanical HDD read-head or actuator failure
  4. SMART-reported impending disk failure

Explanation

Correct Answer

D:

Health attributes exceed vendor-defined thresholds and the firmware marks the disk at risk, consistent with a smart-reported impending disk failure.

Incorrect Answers

A:

The replacement controller has not imported the existing array metadata and lists members as foreign, consistent with a controller raid metadata or configuration mismatch.

B:

Array management identifies exactly one failed member and the other mirror disk is healthy, consistent with a raid mirror degraded with one surviving member.

C:

SMART and vendor diagnostics show increasing media or seek errors alongside audible clicking, consistent with a mechanical hdd read-head or actuator failure.

Question 736

A freshly imaged PC displays 'no bootable device' after its boot-order settings were reset, though the SSD is detected in UEFI. Which failure mode should the technician prioritize?

  1. Missing storage controller driver or incompatible mode
  2. Boot order points away from installed OS
  3. SSD performance degradation under exhausted free space
  4. SMART-reported impending disk failure

Explanation

Correct Answer

B:

Firmware lists the SSD but selects a nonexistent network or USB boot target first, consistent with a boot order points away from installed os.

Incorrect Answers

A:

The installer sees no disk until the supported RAID/VMD controller driver is supplied, consistent with a missing storage controller driver or incompatible mode.

C:

Sustained write benchmarks improve when adequate spare capacity and TRIM operation are restored, consistent with a ssd performance degradation under exhausted free space.

D:

Health attributes exceed vendor-defined thresholds and the firmware marks the disk at risk, consistent with a smart-reported impending disk failure.

Question 737

A help-desk ticket states: A RAID 1 storage pair reports a degraded status after one drive was physically removed, but the shared folder remains online. Which diagnosis is best supported rather than simply possible?

  1. SMART-reported impending disk failure
  2. Storage IOPS contention under concurrent load
  3. Controller RAID metadata or configuration mismatch
  4. RAID mirror degraded with one surviving member

Explanation

Correct Answer

D:

Array management identifies exactly one failed member and the other mirror disk is healthy, consistent with a raid mirror degraded with one surviving member.

Incorrect Answers

A:

Health attributes exceed vendor-defined thresholds and the firmware marks the disk at risk, consistent with a smart-reported impending disk failure.

B:

Queue depth and response time rise with backup traffic while disk health reports no failure, consistent with a storage iops contention under concurrent load.

C:

The replacement controller has not imported the existing array metadata and lists members as foreign, consistent with a controller raid metadata or configuration mismatch.

Question 738

When comparing several hypotheses, a technician observes: After a storage controller replacement, a multi-disk RAID set appears as several unconfigured disks although the drives themselves pass health checks. Which condition best fits?

  1. Controller RAID metadata or configuration mismatch
  2. Missing storage controller driver or incompatible mode
  3. RAID mirror degraded with one surviving member
  4. SMART-reported impending disk failure

Explanation

Correct Answer

A:

The replacement controller has not imported the existing array metadata and lists members as foreign, consistent with a controller raid metadata or configuration mismatch.

Incorrect Answers

B:

The installer sees no disk until the supported RAID/VMD controller driver is supplied, consistent with a missing storage controller driver or incompatible mode.

C:

Array management identifies exactly one failed member and the other mirror disk is healthy, consistent with a raid mirror degraded with one surviving member.

D:

Health attributes exceed vendor-defined thresholds and the firmware marks the disk at risk, consistent with a smart-reported impending disk failure.

Question 739

A technician investigates this device problem: A virtual host's storage remains online but latency spikes during backup windows and monitoring shows near-saturated read/write queues. Which diagnosis best explains the observed pattern?

  1. Missing storage controller driver or incompatible mode
  2. Controller RAID metadata or configuration mismatch
  3. RAID mirror degraded with one surviving member
  4. Storage IOPS contention under concurrent load

Explanation

Correct Answer

D:

Queue depth and response time rise with backup traffic while disk health reports no failure, consistent with a storage iops contention under concurrent load.

Incorrect Answers

A:

The installer sees no disk until the supported RAID/VMD controller driver is supplied, consistent with a missing storage controller driver or incompatible mode.

B:

The replacement controller has not imported the existing array metadata and lists members as foreign, consistent with a controller raid metadata or configuration mismatch.

C:

Array management identifies exactly one failed member and the other mirror disk is healthy, consistent with a raid mirror degraded with one surviving member.

Question 740

A user copies a project to a removable USB drive, and files become corrupt only when the cable is touched. Which underlying component or configuration issue is most consistent with the evidence?

  1. RAID mirror degraded with one surviving member
  2. Disconnected or defective SATA data path
  3. Intermittent external drive cable or connector
  4. SMART-reported impending disk failure

Explanation

Correct Answer

C:

I/O errors correlate with movement and disappear with a known-good cable and port, consistent with an intermittent external drive cable or connector.

Incorrect Answers

A:

Array management identifies exactly one failed member and the other mirror disk is healthy, consistent with a raid mirror degraded with one surviving member.

B:

The drive's power lead is connected but the SATA data cable is loose or fails a known-good swap, consistent with a disconnected or defective sata data path.

D:

Health attributes exceed vendor-defined thresholds and the firmware marks the disk at risk, consistent with a smart-reported impending disk failure.

CompTIA A+ Certification Exam: Core 1 (220-1201) Practice Tests